Incidence and Predictors of Permanent Pacemaker Requirement after Transcatheter Aortic Valve Implantation with a Self-Expanding Bioprosthesis
- 17 August 2010
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 33 (11) , 1364-1372
Abstract
Background: Previous reports have suggested the occurrence of cardiac conduction disorders and permanent pacemaker (PPM) requirement after transcatheter aortic valve implantation (TAVI). Based on a single-center experience, we aim to assess the incidence of postprocedural conduction disorders, need for PPM, and its determinants after TAVI with a self-expanding bioprosthesis. Methods: From August 2007 to October 2009, 32 consecutive patients underwent TAVI with the Medtronic CoreValve (MCV) System (Medtronic Inc., Minneapolis, MN, USA). Three patients paced at baseline and two cases of procedure-related mortality were excluded. We analyzed the 12-lead electrocardiogram at baseline, immediately after procedure and at discharge. Requirements for PPM were documented and potential clinical, electrophysiological, echocardiographic, and procedural predictors of PPM requirement were studied. Results: After TAVI, eight patients (29.6%) required PPM implantation due to high-grade atrioventricular (AV) block. The prevalence of left bundle branch block increased from 13.8% to 57.7% directly after implantation (P = 0.001). Need for PPM was correlated to the depth of prosthesis implantation (r = 0.590; P = 0.001). At a cutoff point of 10.1 mm, the likelihood of pacemaker could be predicted with 87.5% sensitivity and 74% specificity and a receiver operator characteristic curve area of 0.86 ± 0.07 (P = 0.003). Of the seven patients with preexisting right bundle branch block (RBBB), four (57.1%) required PPM implantation after TAVI. Conclusions: High-grade AV block requiring PPM implantation is a common complication following TAVI and could be predicted by a deeper implantation of the prosthesis. Patients with preexisting RBBB also seem to be at risk for the development of high-grade AV block and subsequent pacemaker implantation. (PACE 2010; 1364–1372)Keywords
This publication has 24 references indexed in Scilit:
- Outcomes and Safety of Percutaneous Aortic Valve ReplacementJACC, 2009
- Contemporary surgical or percutaneous management of severe aortic stenosis in the elderlyEuropean Heart Journal, 2008
- Permanent Pacemaker Implantation After Isolated Aortic Valve Replacement: Incidence, Indications, and PredictorsThe Annals of Thoracic Surgery, 2008
- Treatment of Calcific Aortic Stenosis With the Percutaneous Heart ValveJACC, 2006
- Prognostic significance of newly acquired bundle branch block after aortic valve replacementThe American Journal of Cardiology, 2004
- Risk factors for pacemaker implantation following aortic valve replacement: a single centre experienceHeart, 2003
- Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic StenosisCirculation, 2002
- Atrioventricular Conduction Abnormalities in Patients Undergoing Isolated Aortic or Mitral Valve ReplacementPacing and Clinical Electrophysiology, 1985
- Syncope and sudden death in aortic stenosisThe American Journal of Cardiology, 1969
- Calcific Aortic Valvular Disease Associated with Complete Heart BlockDiseases of the Chest, 1968