Evaluation of One- and Two-Step Impression Techniques and Vertical Marginal Misfit in Fixed Prothesis
Open Access
- 21 February 2023
- journal article
- research article
- Published by Wiley in International Journal of Dentistry
- Vol. 2023, 1-6
Abstract
Objectives/Purposes. This study compared one-step and two-step impression techniques. Methods. 12 impressions were made of a resin maxillary model (second premolar and second molar) with two prepared abutment teeth using vinyl polysiloxane (VPS); the margin of the second premolar was 0.5mm subgingivally; and the margin of the second molar tooth was at the level of the gingiva. Impressions were made using two techniques: one-step and two-step putty/light materials. A three-unit metal framework was fabricated on the master model using the computer-aided design/computer-aided manufacturing (CAD/CAM) technique. The vertical marginal misfit was evaluated in the buccal, lingual, and mesial and distal surfaces of the abutments on the gypsum casts using a light microscope. Data were analyzed using the independent t-test (αResults. The results showed significantly lower vertical marginal misfit in all six areas evaluated around the two abutments in the two-step impression technique compared with the corresponding values in the one-step technique. Conclusion. Vertical marginal misfit in the two-step technique with a preliminary putty impression was significantly lower than in the one-step putty/light-body technique.Keywords
Funding Information
- Tehran University of Medical Sciences and Health Services (97-02-70-38938)
This publication has 17 references indexed in Scilit:
- Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro StudyJournal of Clinical and Diagnostic Research, 2016
- Experimental study on the use of spacer foils in two-step putty and wash impression procedures using silicone impression materialsThe Journal of Prosthetic Dentistry, 2015
- Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study.2013
- The Effect of One‐Step vs. Two‐Step Impression Techniques on Long‐Term Accuracy and Dimensional Stability when the Finish Line is within the Gingival Sulcular AreaJournal of Prosthodontics, 2013
- A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression MaterialThe Journal of Indian Prosthodontic Society, 2013
- Internal adaptation, marginal accuracy and microleakage of a pressable versus a machinable ceramic laminate veneersJournal of Dentistry, 2012
- Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: An in vitro studyThe Journal of Prosthetic Dentistry, 2008
- A review of contemporary impression materials and techniquesDental Clinics of North America, 2004
- Polyvinyl siloxane impression materials: A review of properties and techniquesThe Journal of Prosthetic Dentistry, 1992
- Time-dependent accuracy of elastomer impression materials. Part II: Polyether, polysulfides, and polyvinylsiloxaneThe Journal of Prosthetic Dentistry, 1981