Comment on “Innovative scattering analysis shows that hydrophobic disordered proteins are expanded in water”
- 31 August 2018
- journal article
- editorial
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 361 (6405) , eaau8230
Abstract
Editors at Science requested our input on the above discussion (comment by Best et al . and response by Riback et al .) because both sets of authors use our data from Fuertes et al . (2017) to support their arguments. The topic of discussion pertains to the discrepant inferences drawn from SAXS versus FRET measurements regarding the dimensions of intrinsically disordered proteins (IDPs) in aqueous solvents. Using SAXS measurements on labeled and unlabeled proteins, we ruled out the labels used for FRET measurements as the cause of discrepant inferences between the two methods. Instead, we propose that FRET and SAXS provide complementary readouts because of a decoupling of size and shape fluctuations that is intrinsic to finite-sized, heteropolymeric IDPs. Accounting for this decoupling resolves the discrepant inferences between the two methods, thus making a case for the utility of both methods.Keywords
This publication has 9 references indexed in Scilit:
- Response to Comment on “Innovative scattering analysis shows that hydrophobic disordered proteins are expanded in water”Science, 2018
- Comment on “Innovative scattering analysis shows that hydrophobic disordered proteins are expanded in water”Science, 2018
- Innovative scattering analysis shows that hydrophobic disordered proteins are expanded in waterScience, 2017
- Conformational Heterogeneity and FRET Data Interpretation for Dimensions of Unfolded ProteinsBiophysical Journal, 2017
- Decoupling of size and shape fluctuations in heteropolymeric sequences reconciles discrepancies in SAXS vs. FRET measurementsProceedings of the National Academy of Sciences, 2017
- Consistent View of Polypeptide Chain Expansion in Chemical Denaturants from Multiple Experimental MethodsJournal of the American Chemical Society, 2016
- Random coil negative control reproduces the discrepancy between scattering and FRET measurements of denatured protein dimensionsProceedings of the National Academy of Sciences, 2015
- SASBDB, a repository for biological small-angle scattering dataNucleic Acids Research, 2014
- How accurate are polymer models in the analysis of Förster resonance energy transfer experiments on proteins?The Journal of Chemical Physics, 2009