Reference Measurement Procedure for Total Glycerides by Isotope Dilution GC-MS
Open Access
- 1 April 2012
- journal article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 58 (4) , 768-776
Abstract
BACKGROUND: The CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing. The CA RMP has several disadvantages, including lack of ruggedness. It uses obsolete instrumentation and hazardous reagents. To overcome these problems the CDC developed an isotope dilution GC-MS (ID-GC-MS) RMP for total glycerides in serum.METHODS: We diluted serum samples with Tris-HCl buffer solution and spiked 200-μL aliquots with [13C3]-glycerol. These samples were incubated and hydrolyzed under basic conditions. The samples were dried, derivatized with acetic anhydride and pyridine, extracted with ethyl acetate, and analyzed by ID-GC-MS. Linearity, imprecision, and accuracy were evaluated by analyzing calibrator solutions, 10 serum pools, and a standard reference material (SRM 1951b).RESULTS: The calibration response was linear for the range of calibrator concentrations examined (0–1.24 mmol/L) with a slope and intercept of 0.717 (95% CI, 0.7123–0.7225) and 0.3122 (95% CI, 0.3096–0.3140), respectively. The limit of detection was 14.8 μmol/L. The mean %CV for the sample set (serum pools and SRM) was 1.2%. The mean %bias from NIST isotope dilution MS values for SRM 1951b was 0.7%.CONCLUSIONS: This ID-GC-MS RMP has the specificity and ruggedness to accurately quantify total glycerides in the serum pools used in the CDC's Lipid Standardization Program and demonstrates sufficiently acceptable agreement with the NIST primary RMP for total glyceride measurement.Keywords
Funding Information
- National Heart, Lung, and Blood Institute
- Division for Heart and Stroke Prevention
- National Center for Chronic Disease Prevention and Health Promotion
- CDC
This publication has 18 references indexed in Scilit:
- Proposed Serum Cholesterol Reference Measurement Procedure by Gas Chromatography–Isotope Dilution Mass SpectrometryClinical Chemistry, 2011
- The Role of and the Place of Method Validation in Drug Analysis Using Electroanalytical TechniquesThe Open Analytical Chemistry Journal, 2011
- Quantitative Analysis of Urinary Glycerol Levels for Doping Control Purposes Using Gas Chromatography-Mass SpectrometryEuropean Journal of Mass Spectrometry, 2008
- A new combined multicompartmental model for apolipoprotein B-100 and triglyceride metabolism in VLDL subfractionsJournal of Lipid Research, 2005
- Determination of Glycerol Concentrations and Glycerol Isotopic Enrichments in Human Plasma by Gas Chromatography/Mass SpectrometryAnalytical Biochemistry, 1998
- Comparing Two Methods of Clinical Measurement: A Personal HistoryInternational Journal of Epidemiology, 1995
- Plasma triglyceride and LDL heterogeneity in familial combined hyperlipidemia.Arteriosclerosis and Thrombosis: A Journal of Vascular Biology, 1993
- Determination of “free” glycerol in human serum reference materials by isotope-dilution gas chromatography—mass spectrometryJournal of Chromatography B: Biomedical Sciences and Applications, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Analysis of linear approaches to quantitative stable isotope methodology in mass spectrometryJournal of Mass Spectrometry, 1981