Capnometry and Air Insufflation for Assessing Initial Placement of Gastric Tubes
Authors:
- 1 November 2007
- journal article
- research article
- Published by AACN Publishing in American Journal of Critical Care
- Vol. 16 (6) , 544-549
Abstract
Background Nurses are often responsible for placement of large-bore gastric tubes. Tube misplacement into the lungs is a potential complication with serious sequelae. The reliability of common bedside methods for differentiating between pulmonary and gastric placement has not been acceptable. Objective To compare the accuracy of capnometry (colorimetric indicator of end-tidal carbon dioxide) and air insufflation/auscultation with the accuracy of radiography in detecting the location of gastric tubes. Methods A prospective convenience sample of insertions of Salem sump gastric tubes was studied. Tubes were inserted by nurses according to the unit’s standard procedure, and air insufflation/auscultation, capnometry, and radiography were used to detect the position of the tubes. Results obtained with each of the methods were compared. Results A total of 91 tube placements were studied in 69 patients. No radiographically documented instances of lung placement occurred. Capnometry incorrectly indicated 15 of 91 gastric placements (16%) as placements in the lung. Air insufflation/auscultation incorrectly indicated 5 of 91 gastric placements (5%) as placements in the lung. Conclusions Neither air insufflation nor capnometry is a fail-safe method for determining placement of gastric tubes. Radiography remains the preferred method.Keywords
This publication has 13 references indexed in Scilit:
- Detection of Inadvertent Airway Intubation During Gastric Tube Insertion: Capnography Versus a Colorimetric Carbon Dioxide DetectorAmerican Journal of Critical Care, 2006
- Malpositioning of fine bore feeding tube: A serious complicationActa Anaesthesiologica Scandinavica, 2005
- The effect of vinegar on colorimetric end-tidal carbon dioxide determination after esophageal intubationThe Journal of Emergency Medicine, 2005
- Patient safety: effect of institutional protocols on adverse events related to feeding tube placement in the critically ill1Journal of the American College of Surgeons, 2004
- Evaluation of an end-tidal portable ETCO2 colorimetric breath indicator (COLIBRI)The American Journal of Emergency Medicine, 2004
- Use of capnometry to verify feeding tube placementCritical Care Medicine, 2002
- Rapid detection of oesophageal intubation: take care when using colorimetric capnometryActa Anaesthesiologica Scandinavica, 2002
- Capnography confirms correct feeding tube placement in intensive care unit patientsCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2001
- Assessing Placement of Feeding TubesAJN, American Journal of Nursing, 2001
- Report on the development of a procedure to prevent placement of feeding tubes into the lungs using end-tidal CO2 measurementsCritical Care Medicine, 2001