Estimating suspended sediment concentrations from turbidity measurements and the calibration problem
- 13 August 2007
- journal article
- research article
- Published by Wiley in Hydrological Processes
- Vol. 22 (12) , 1819-1830
Abstract
In situ turbidity meters are being increasingly used to generate continuous records of suspended sediment concentration in rivers. However, the usefulness of the information obtained depends heavily on the existence of a close relationship between fluctuations in suspended sediment concentration and turbidity and the calibration procedure that relates suspended sediment concentration to the turbidity meter's signal. This study assesses the relationship between suspended sediment concentration and turbidity for a small (1·19 km2) rural catchment in southern Brazil and evaluates two calibration methods by comparing the estimates of suspended sediment concentration obtained from the calibrated turbidity readings with direct measurements obtained using a USDH 48 suspended sediment sampler. With the first calibration method, the calibration relationship is derived by relating the turbidity readings to simultaneous measurements of concentration obtained from suspended sediment samples collected from the vicinity of the turbidity probe during flood events. With the second method, the calibration is based on the readings obtained from the turbidity meter when the probe immersed in samples of known concentration prepared using soils collected from the catchment. Overall, there was a close link between fluctuations in suspended sediment concentration and turbidity in the stream at the outlet of the catchment, and the estimates of sediment concentration obtained using the first calibration method corresponded closely with the conventionally measured sediment concentrations. However, use of the second calibration method introduced appreciable errors. When the estimated sediment concentrations were compared with the measured values, the mean errors were ± 122 mg l−1 and + 601 mg l−1 for the first and second calibration procedures respectively. Copyright © 2007 John Wiley & Sons, Ltd.Keywords
This publication has 19 references indexed in Scilit:
- Impacts of land use change on patterns of sediment flux in Weraamaia catchment, New ZealandCATENA, 2005
- Can flocs and water stable soil aggregates be differentiated within fluvial systems?CATENA, 2005
- SPECTROPHOTOMETRY | Turbidimetry and Nephelometry2005
- Influences of human activities on sediment discharge from devastated weathered granite hills of southern China: effects of 4-year elimination of human activitiesCATENA, 2002
- TURBIDITY SUSPENI)ED SEDIMENT, AND WATER CLARITY: A REVIEW1Jawra Journal of the American Water Resources Association, 2001
- Processes controlling sediment yield from watersheds as functions of spatial scaleEnvironmental Modelling & Software, 1997
- Potential of turbidity monitoring for measuring the transport of suspended solids in streamsHydrological Processes, 1995
- The relation of stream sediment surface area, grain size and composition to trace element chemistryApplied Geochemistry, 1987
- Field calibration of a recording turbidity meterCATENA, 1985
- Sediment yield and land use in tropical catchmentsJournal of Hydrology, 1979