An ultra-high performance parallel (UHPP) framework for complex 4π radiotherapy planning
Open Access
- 6 August 2025
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (16) , 165004
Abstract
Purpose. In radiotherapy, dose distribution conformity and compactness are critical to patient outcomes. Advanced techniques like 4 π radiotherapy leverage non-coplanar beams for superior dosimetry by exploring additional degrees of freedom. However, 4 π planning is computationally intensive due to large dose-loading matrices for candidate beams. This work presents an ultra-high performance parallel (UHPP) framework to accelerate high-dimensional treatment planning. Methods. For dose calculation, we developed: (1) a two-step total energy released per unit mass (TERMA) computation module calculating the TERMA array once per beam, enabling reuse across convolution directions; (2) a synchronized dose calculation module based on collapsed-cone convolution superposition (CCCS), arranging rays in dedicated sequences to preserve thread efficiency and minimize memory access; (3) a scattering-based coordinate transformation mapping dose from beamlet to patient Cartesian coordinates, eliminating aliasing without atomic operations. The framework includes CCCS exponential kernel calculation for varying LINAC spectra. For beam orientation optimization, we employed fast iterative shrinkage-thresholding algorithm with group sparsity regularization, accelerated using cuSPARSE library on GPUs. We benchmarked against Monte Carlo (MC) simulations for dose accuracy and compared computational performance to state-of-the-art (SOTA) methods. Plan quality was evaluated across four approaches: UHPP, SOTA, clinical VMAT plans, and MC calculations based on UHPP plans. Results. Compared to MC simulations, UHPP achieved minimum 98% gamma passing rates under 1.5%/1.5 mm criterion for water and slab phantoms, and average 97.35% and 92.18% under 3%/3 mm criterion for pancreas and head-and-neck patients, respectively. UHPP delivered 8.86× and 6.99× speedups in dose calculation and plan optimization while maintaining comparable or superior plan quality. Both UHPP and SOTA consistently produced 4 π plans outperforming clinical VMAT plans in organ-at-risk sparing and target coverage. Conclusion. The UHPP framework delivers high dose accuracy and substantial computational speedup without sacrificing 4 π planning’s dosimetric advantages, supporting practical adoption of advanced 4 π radiotherapy in clinical workflows.Keywords
Funding Information
- NIH (R01CA230278)
This publication has 32 references indexed in Scilit:
- Quantification of Dosimetry Improvement With or Without Patient Surface GuidanceAdvances in Radiation Oncology, 2024
- Dosimetrically motivated beam‐angle optimization for non‐coplanar arc radiotherapy with and without dynamic collimator rotationMedical Physics, 2023
- Fully automated noncoplanar radiation therapy treatment planningMedical Physics, 2021
- Parallel beamlet dose calculation via beamlet contexts in a distributed multi‐GPU frameworkMedical Physics, 2019
- A Prospective 4π Radiation Therapy Clinical Study in Recurrent High-Grade Glioma PatientsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2018
- VMAT optimization with dynamic collimator rotationMedical Physics, 2018
- Integrated beam orientation and scanning‐spot optimization in intensity‐modulated proton therapy for brain and unilateral head and neck tumorsMedical Physics, 2018
- Low Rank Priors for Color Image Regularization2015
- 4π Noncoplanar Stereotactic Body Radiation Therapy for Centrally Located or Larger Lung TumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013
- 4π Non-Coplanar Liver SBRT: A Novel Delivery TechniqueInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2013