Nonlinear greedy sparsity-constrained algorithm for direct reconstruction of fluorescence molecular lifetime tomography
Authors:
Open Access
- 9 March 2016
- journal article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7 (4) , 1210-1226
Abstract
In order to improve the spatial resolution of time-domain (TD) fluorescence molecular lifetime tomography (FMLT), an accelerated nonlinear orthogonal matching pursuit (ANOMP) algorithm is proposed. As a kind of nonlinear greedy sparsity-constrained methods, ANOMP can find an approximate solution of L0 minimization problem. ANOMP consists of two parts, i.e., the outer iterations and the inner iterations. Each outer iteration selects multiple elements to expand the support set of the inverse lifetime based on the gradients of a mismatch error. The inner iterations obtain an intermediate estimate based on the support set estimated in the outer iterations. The stopping criterion for the outer iterations is based on the stability of the maximum reconstructed values and is robust for problems with targets at different edge-to-edge distances (EEDs). Phantom experiments with two fluorophores at different EEDs and in vivo mouse experiments demonstrate that ANOMP can provide high quantification accuracy, even if the EED is relatively small, and high resolution.Keywords
Funding Information
- National Major Scientific Instrument and Equipment Development Project (2011YQ030114)
- National Natural Science Foundation of China (NSFC) (61322101, 61361160418, 81227901, 81271617)
This publication has 36 references indexed in Scilit:
- In vivo fluorescence lifetime tomography of a FRET probe expressed in mouseBiomedical Optics Express, 2011
- In vivo fluorescence lifetime tomographyJournal of Biomedical Optics, 2009
- Fluorescence lifetime properties of near-infrared cyanine dyes in relation to their structuresJournal of Photochemistry and Photobiology A: Chemistry, 2008
- Molecular imaging in drug developmentNature Reviews Drug Discovery, 2008
- Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data setsMedical Physics, 2008
- Honest variable selection in linear and logistic regression models via ℓ1 and ℓ1+ℓ2 penalizationElectronic Journal of Statistics, 2008
- Tomographic bioluminescence imaging by use of a combined optical-PET (OPET) system: a computer simulation feasibility studyPhysics in Medicine & Biology, 2005
- Greed is Good: Algorithmic Results for Sparse ApproximationIEEE Transactions on Information Theory, 2004
- Fluorescence lifetime imaging in turbid mediaOptics Letters, 1996
- Matching pursuits with time-frequency dictionariesIEEE Transactions on Signal Processing, 1993