Selection of individual variables versus intervals of variables in PLSR
Authors:
- 12 January 2010
- journal article
- research article
- Published by Wiley in Journal of Chemometrics
- Vol. 24 (2) , 45-56
Abstract
The selection abilities of the two well‐known techniques of variable selection, synergy interval‐partial least‐squares (SiPLS) and genetic algorithm‐partial least‐squares (GA‐PLS), have been examined and compared. By using different simulated and real (corn and metabolite) datasets, keeping in view the spectral overlapping of the components, the influence of the selection of either intervals of variables or individual variables on the prediction performances was examined. In the simulated datasets, with decrease in the overlapping of the spectra of components and cases with components of narrow bands, GA‐PLS results were better. In contrast, the performance of SiPLS was higher for data of intermediate overlapping. For mixtures of high overlapping analytes, GA‐PLS showed slightly better performance. However, significant differences between the results of the two selection methods were not observed in most of the cases. Although SiPLS resulted in slightly better performance of prediction in the case of corn dataset except for the prediction of the moisture content, the improvement obtained by SiPLS compared with that by GA‐PLS was not significant. For real data of less overlapped components (metabolite dataset), GA‐PLS that tends to select far fewer variables did not give significantly better root mean square error of cross‐validation (RMSECV), cross‐validated R2 (Q2), and root mean square error of prediction (RMSEP) compared with SiPLS. Irrespective of the type of dataset, GA‐PLS resulted in models with fewer latent variables (LVs). When comparing the computational time of the methods, GA‐PLS is considered superior to SiPLS. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
This publication has 23 references indexed in Scilit:
- Variable selection for multivariate calibration using a genetic algorithm: prediction of additive concentrations in polymer films from Fourier transform-infrared spectral dataAnalytica Chimica Acta, 2002
- Multiple Linear Regression Calibrations for Barley and Malt Protein Based on the Spectra of HordeinJournal of the Institute of Brewing, 2002
- PLS-regression: a basic tool of chemometricsChemometrics and Intelligent Laboratory Systems, 2001
- Development of robust calibration models in near infra-red spectrometric applicationsAnalytica Chimica Acta, 2000
- Interval Partial Least-Squares Regression ( i PLS): A Comparative Chemometric Study with an Example from Near-Infrared SpectroscopyApplied Spectroscopy, 2000
- Genetic algorithms applied to feature selection in PLS regression: how and when to use themChemometrics and Intelligent Laboratory Systems, 1998
- Genetic algorithms as a method for variable selection in multiple linear regression and partial least squares regression, with applications to pyrolysis mass spectrometryAnalytica Chimica Acta, 1997
- Comparison of multivariate methods based on latent vectors and methods based on wavelength selection for the analysis of near-infrared spectroscopic dataAnalytica Chimica Acta, 1995
- A Primer on Multivariate CalibrationAnalytical Chemistry, 1994
- The partial least squares-fix point method of estimating interdependent systems with latent variablesCommunications in Statistics - Theory and Methods, 1981