Closed-Loop Coadministration of Propofol and Remifentanil Guided by Bispectral Index
Authors:
- Thierry ChazotTCThierry Chazot
- Sophie HamadaSHSophie Hamada
- Alain LandaisALAlain Landais
- Nathalie BoichutNBNathalie Boichut
- Corinne DussaussoyCDCorinne Dussaussoy
- Bernard TrillatBTBernard Trillat
- Laurent BeydonLBLaurent Beydon
- Emmanuel SamainESEmmanuel Samain
- Daniel I. SesslerDSDaniel I. Sessler
- Marc FischlerMFMarc Fischler
- 1 March 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 112 (3) , 546-557
Abstract
We have developed a proportional-integral-derivative controller allowing the closed-loop coadministration of propofol and remifentanil, guided by a Bispectral Index (BIS) monitor, during induction and maintenance of general anesthesia. The controller was compared with manual target-controlled infusion. In a multicenter study, 196 surgical patients were randomly assigned to dual closed-loop or manual administration of propofol and remifentanil. Comparison between groups was evaluated by calculating a global score that characterized the overall performance of the controller including the percentage of adequate anesthesia, defined as BIS between 40 and 60, the median absolute performance error, and wobble. Secondary outcomes included occurrence of burst suppression ratio, time to tracheal extubation, and drug consumption. Eighty-three patients assigned to dual-loop control and 84 patients assigned to manual control completed the study. The global score and the percentage of time with BIS between 40 and 60 were better in the dual-loop group (26 ± 11 vs 43 ± 40, P < 0.0001; 82% ± 12% vs 71% ± 19%, P < 0.0001). Overshoot (BIS 60), and burst suppression ratio were all significantly less common in the dual-loop group. Modifications to the propofol and remifentanil infusions were more frequent, and adjustments smaller in the dual-loop group. Remifentanil consumption was greater (0.22 ± 0.07 vs 0.16 ± 0.07 μg · kg(-1) · min(-1); P < 0.0001) and the speed to tracheal extubation was shorter (10 ± 4 vs 11 ± 5 minutes; P = 0.02) in the dual-loop group. The controller allows the automated delivery of propofol and remifentanil and maintains BIS values in predetermined boundaries during general anesthesia better than manual administration.Keywords
This publication has 37 references indexed in Scilit:
- Adaptive computer control of anesthesia in humansComputer Methods in Biomechanics and Biomedical Engineering, 2009
- Presence of electroencephalogram burst suppression in sedated, critically ill patients is associated with increased mortalityCritical Care Medicine, 2008
- Closed‐loop administration of propofol and remifentanil guided by the Bispectral Index in patient requiring an emergency lung volume reductionPediatric Anesthesia, 2007
- Closed-loop Control of Mean Arterial Blood Pressure during Surgery with AlfentanilAnesthesiology, 2006
- The Effect of the Interaction of Propofol and Alfentanil on Recall, Loss of Consciousness, and the Bispectral IndexAnesthesia & Analgesia, 1998
- The Effect of the Interaction of Propofol and Alfentanil on Recall, Loss of Consciousness, and the Bispectral IndexAnesthesia & Analgesia, 1998
- Anesthetic Drug InteractionsAnesthesiology, 1998
- PROPOFOL ACTIVATES THE GABAA RECEPTOR-IONOPHORE COMPLEX IN DISSOCIATED HIPPOCAMPAL NEURONS OF THE RATAnesthesiology, 1992
- The Use of Computers for Controlling the Delivery of AnesthesiaAnesthesiology, 1992
- Measuring the predictive performance of computer-controlled infusion pumpsJournal of Pharmacokinetics and Biopharmaceutics, 1992