Assessment of acetone as an alternative to acetonitrile in peptide analysis by liquid chromatography/mass spectrometry
Authors:
- 10 June 2009
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (14) , 2139-2145
Abstract
Acetonitrile as a solvent used in liquid chromatography/mass spectrometry (LC/MS) of peptides and proteins is a relatively toxic solvent (LD 50 oral; rat; 2,460 mg/kg) compared to alternatives like methanol (LD 50 oral; rat; 5,628 mg/kg) and acetone (LD 50 oral; rat; 5,800 mg/kg). Strategies to minimize its consumption in LC are either to reduce the inner diameter of the column or replace acetonitrile with a suitable alternative. Methanol is often recommended to replace acetonitrile in peptide analysis. In this study however, the main focus lies on another alternative solvent for LC/MS of peptides; acetone. A number of model proteins were tryptically digested and the peptide solutions were analyzed on a linear trap quadrupole (LTQ) mass spectrometer. The performances of acetonitrile, methanol and acetone were compared according to the quality of the chromatograms obtained and identification of the peptides using the BioWorks™ software developed by Thermo Scientific. In accordance to the elutropic series, acetone was found to significantly reduce the retention times of peptides separated by C18 column material with regard to acetonitrile while methanol led to increased retention times. Acetone was the superior solvent to methanol for most of the tested model proteins reaching similar sequence coverage and numbers of identified peptides as acetonitrile. We therefore propose acetone as an alternative to acetonitrile in LC/MS of peptides. Copyright © 2009 John Wiley & Sons, Ltd.Keywords
Funding Information
- BMBF within the project Bio-OK and the DFG graduate school 1213 ‘Sustainability in catalysis and technique’
This publication has 8 references indexed in Scilit:
- A SOLVENT DRIES UPChemical & Engineering News, 2008
- Identification of N-Linked Glycosylation Sites Using Glycoprotein Digestion with Pronase Prior to MALDI Tandem Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2007
- Mass Spectral Analysis in ProteomicsAnnual Review of Biophysics, 2004
- Trypsin Cleaves Exclusively C-terminal to Arginine and Lysine ResiduesMolecular & Cellular Proteomics, 2004
- Practical implications of some recent studies in electrospray ionization fundamentalsMass Spectrometry Reviews, 2001
- Identifying the proteome: software toolsCurrent Opinion in Biotechnology, 2000
- Protein mass spectrometry: applications to analytical biotechnologyJournal of Chromatography A, 1995
- Peptide Mass Maps: A Highly Informative Approach to Protein IdentificationAnalytical Biochemistry, 1993