Impact of the frequency of online verifications on the patient set-up accuracy and set-up margins
Open Access
- 24 August 2011
- journal article
- Published by Springer Nature in Radiation Oncology
- Vol. 6 (1) , 101
Abstract
The purpose of the study was to evaluate the patient set-up error of different anatomical sites, to estimate the effect of different frequencies of online verifications on the patient set-up accuracy, and to calculate margins to accommodate for the patient set-up error (ICRU set-up margin, SM). Alignment data of 148 patients treated with inversed planned intensity modulated radiotherapy (IMRT) or three-dimensional conformal radiotherapy (3D-CRT) of the head and neck (n = 31), chest (n = 72), abdomen (n = 15), and pelvis (n = 30) were evaluated. The patient set-up accuracy was assessed using orthogonal megavoltage electronic portal images of 2328 fractions of 173 planning target volumes (PTV). In 25 patients, two PTVs were analyzed where the PTVs were located in different anatomical sites and treated in two different radiotherapy courses. The patient set-up error and the corresponding SM were retrospectively determined assuming no online verification, online verification once a week and online verification every other day. The SM could be effectively reduced with increasing frequency of online verifications. However, a significant frequency of relevant set-up errors remained even after online verification every other day. For example, residual set-up errors larger than 5 mm were observed on average in 18% to 27% of all fractions of patients treated in the chest, abdomen and pelvis, and in 10% of fractions of patients treated in the head and neck after online verification every other day. In patients where high set-up accuracy is desired, daily online verification is highly recommended.Keywords
This publication has 33 references indexed in Scilit:
- Planning target volume margins for prostate radiotherapy using daily electronic portal imaging and implanted fiducial markersRadiation Oncology, 2010
- Comparison of geometric uncertainties using electronic portal imaging device in focal three-dimensional conformal radiation therapy using different head supportsJournal of Cancer Research and Therapeutics, 2008
- Assessment of three-dimensional set-up errors in conventional head and neck radiotherapy using electronic portal imaging deviceRadiation Oncology, 2007
- Phantom and in-vivo measurements of dose exposure by image-guided radiotherapy (IGRT): MV portal images vs. kV portal images vs. cone-beam CTRadiotherapy and Oncology, 2007
- Intensity-Modulated Radiotherapy Using Implanted Fiducial Markers With Daily Portal Imaging: Assessment of Prostate Organ MotionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Developments in electronic portal imaging systemsBritish Journal of Radiology, 2006
- Correction of systematic setup errors in prostate radiation therapy: How many images to perform?Medical Dosimetry, 2005
- Geometrical uncertainties, radiotherapy planning margins, and the ICRU-62 reportRadiotherapy and Oncology, 2002
- Positioning errors and prostate motion during conformal prostate radiotherapy using on-line isocentre set-up verification and implanted prostate markersRadiotherapy and Oncology, 2001
- Influence of the positioning error on 3D conformal dose distributions during fractionated radiotherapyRadiotherapy and Oncology, 1994