The Effect of Moisture on Firefighter Protective Clothing Thermal Insulation: A Review of Industry Research
Author:
- 1 January 2000
- book chapter
- Published by ASTM International
- p. 557-576
Abstract
Despite advances in the new material technology and clothing designs for protecting firefighters, firefighters may still be burned under routine or ordinary fire fighting conditions. Some theories indicate that moisture in the clothing, resulting both internally from firefighters sweating and externally by hose spray or runoff, may be one cause of these injuries. An extensive review of industry research for evaluating the thermal insulation of firefighter protective clothing shows a range of performance for different material systems under both wet and dry conditions. For the various types of heat transfer, using both conventional and modified testing procedures, there is no conclusion that can be generalized for predicting the effect of water on protective clothing materials system thermal insulation. The body of research in the firefighter protective clothing industry shows some conditions where the tolerance times (time-to-pain and time-to-2nd degree burn), or the time for a specific temperature rise, will favor dry systems over wet systems. Other conditions exist where material systems with varying levels of moisture will provide relatively longer tolerance times or specific times to temperature rise as compared to dry systems. Several factors are demonstrated in the literature that affect the performance of clothing that includes moisture. These factors include the amount of water, its location in the material system, the type of heat transfer, the intensity and duration of exposure, and the type of materials and their condition during testing. The industry review demonstrates different effects for each of these factors. Given the variety of exposure conditions that firefighters face, it is likely that no predictive model will ever be developed that fully explains clothing performance under all conditions. This paper is intended to demonstrate the complexity of the subject and how simple claims for effects of moisture on clothing thermal insulation can be misleading or incorrect under many circumstances.Keywords
This publication has 13 references indexed in Scilit:
- Protecting fire fighters exposed in room fires: Comparison of results of bench scale test for thermal protection and conditions during room flashoverFire Technology, 1988
- Effect of moisture on the burn potential in fire fighters' glovesFire Technology, 1987
- Thermal radiative protection of fire fighters' protective clothingFire Technology, 1987
- A Critical Appraisal of Test Methods for Thermal Protective Clothing Fabrics1986
- Protective Fabrics: A Comparison of Laboratory Methods for Evaluating Thermal Protective Performance in Convective/Radiant ExposuresTextile Research Journal, 1984
- Predicting flash fire protection of clothing from laboratory tests using second‐degree burn to rate performanceFire and Materials, 1984
- Assessment of Ventilation Characteristics of Standard and Prototype Firefighter Protective Clothing1Textile Research Journal, 1980
- Thermal Protective Performance test for clothingFire Technology, 1977
- Protection From Fire: Nonflammable Fabrics and Coatings*Journal of Coated Fabrics, 1976
- HEAT TRANSFER THROUGH FABRICS AS RELATED TO THERMAL INJURY*†Transactions of the New York Academy of Sciences, 1971