Biogenic Fraction of Ambient VOC: Comparison of Radiocarbon, Chromatographic, and Emissions Inventory Estimates for Atlanta, Georgia
Open Access
- 1 March 1999
- journal article
- research article
- Published by Taylor & Francis in Journal of the Air & Waste Management Association
- Vol. 49 (3) , 299-307
Abstract
Previously reported volatile organic compounds (VOC) radiocarbon (14C) measurements for 1992 summertime Atlanta, GA, have been compared with chromatographic data and emissions inventory predictions. The chromatographic approach that was used provided a more comprehensive VOC characterization than typically achieved, and the emissions inventory was research-grade level (date-, site-, and time-specific). The comparisons are in general agreement that biogenic emissions contribute only modestly (<10%) to the VOC content of the particular ambient samples that were collected and measured. The choices of sampling site (near city-center) and times (early morning and late evening) are major influences on the results, which consequently should not be regarded as representing the average VOC biogenic impact for the Atlanta area.Keywords
This publication has 1 reference indexed in Scilit:
- PC-BEIS: A Personal Computer Version of the Biogenic Emissions Inventory SystemJournal of the Air & Waste Management Association, 1991