Deep brain stimulation electrodes may rotate after implantation—an animal study
Open Access
- 30 October 2020
- journal article
- research article
- Published by Springer Nature in Neurosurgical Review
- Vol. 44 (4) , 2349-2353
Abstract
Directional deep brain stimulation (dDBS) electrodes allow to steer the electrical field in a specific direction. When implanted with torque, they may rotate for a certain time after implantation. The aim of this study was to evaluate whether and to which degree leads rotate in the first 24 h after implantation using a sheep brain model. dDBS electrodes were implanted in 14 sheep heads and 3D rotational fluoroscopy (3D-RF) scans were acquired to visualize the orientation of the electrode leads. Electrode leads were clockwise rotated just above the burr holes (180° n = 6, 360° n = 6, 2 controls) and 3D-RF scans were again acquired after 3, 6, 13, 17, and 24 h, respectively. One hundred eighty degree rotated electrodes showed an initial rotation of 83.5° (range: 35.4°–128.3°) and a rotation of 114.0° (range: 57°–162°) after 24 h. With 360° torsion, mean initial rotation was 201° (range: 3.3°–321.4°) and mean rotation after 24 h 215.7° (range 31.9°–334.7°), respectively. Direct postoperative imaging may not be accurate for determining the rotation of dDBS electrodes if torque is present.Keywords
Funding Information
- Universitätsklinikum Freiburg
This publication has 13 references indexed in Scilit:
- An update on best practice of deep brain stimulation in Parkinson’s diseaseTherapeutic Advances in Neurological Disorders, 2019
- DiODe: Directional Orientation Detection of Segmented Deep Brain Stimulation Leads: A Sequential Algorithm Based on CT ImagingStereotactic and Functional Neurosurgery, 2018
- Directional Deep Brain StimulationNeurotherapeutics, 2018
- Determining the Rotational Orientation of Directional Deep Brain Stimulation Leads Employing Flat-Panel Computed TomographyOperative Neurosurgery, 2018
- Postoperative lead migration in deep brain stimulation surgery: Incidence, risk factors, and clinical impactPLOS ONE, 2017
- Determining the orientation angle of directional leads for deep brain stimulation using computed tomography and digital x‐ray imaging: A phantom studyMedical Physics, 2017
- Determining the Orientation of Directional Deep Brain Stimulation Electrodes Using 3D Rotational FluoroscopyAmerican Journal of Neuroradiology, 2017
- Directional deep brain stimulation of the subthalamic nucleus: A pilot study using a novel neurostimulation deviceMovement Disorders, 2016
- Directional deep brain stimulation: an intraoperative double-blind pilot studyBrain, 2014
- Postoperative Curving and Upward Displacement of Deep Brain Stimulation Electrodes Caused by Brain ShiftNeurosurgery, 2010