A New Packing for Aqueous Size Exclusion Chromatography Polyvinylpyrrolidone-Coated Silica
Authors:
- 1 January 1981
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography
- Vol. 4 (8) , 1311-1322
Abstract
Adsorption of polyvinylpyrrolidone on silica in aqueous medium is studied. Adsorption isotherms, thermogravimetry and elementary analysis show that a complete surface coverage is reached with large pore microbeads. The coating stability and its ability to prevent non-steric effects when used as packing in exclusion chromatography are demonstrated. Four different pore size packings were prepared for chromatographic evaluations. It is shown that water soluble polymers like polyethylene oxide, polyvinylalcohol, polyacrylamide and hydroxyethylcellulose can be chromatographied in pure water according to the steric exclusion mechanism.Keywords
This publication has 5 references indexed in Scilit:
- Separation range and separation efficiency in high-speed gel filtration on TSK-GEL SW columnsJournal of Chromatography A, 1980
- High-performance exclusion chromatography of water- soluble polymers with chemically bonded stationary phasesJournal of Chromatography A, 1979
- The Use of Microparticulates in Gel Permeation ChromatographyJournal of Chromatographic Science, 1977
- Adsorption characteristics of polyvinylpyrrolidone at solid-liquid interfaceColloid and Polymer Science, 1977
- The adsorption of a copolymer of vinyl pyrrolidone and allylamine at the silica-solution interfaceEuropean Polymer Journal, 1974