Translation and rotational target motion effect in NSCLC case with 3D-CRT, IMRT, and VMAT techniques using in-house dynamic thorax phantom
Open Access
- 1 June 2019
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1248 (1) , 012065
Abstract
This study aimed to make in-house dynamic thorax phantom that simulate translational and rotational direction mimicking NSCLC target movement. In addition,this study also investigate dosimetric effect of target movement for several translational amplitude. This work used in-house dynamic thorax phantom based on CIRS Dynamic Thorax Phantom model 008A. This phantom simulated translation in superior-inferior direction, rotational in the anterior-posterior and left-right lateral plane to mimic human respiratory motion. It was designed and controlled by linear actuator motor, servo motor, Adafruit motor shield L293D and Arduino UNO R3. It was implemented to evaluate point dose of 3D-CRT, IMRT, VMAT technique and for 5 mm; 10 mm; 15 mm translational motion amplitude 90° rotational target motion amplitude. The GafChromic EBT 3 film was used as a dosimeter for point dose measurement. This in-house dynamic thorax phantom can mimicking NSCLC target movement for translational amplitude 5 ± 1 mm; 10 ± 1 mm; 15 ± 1 mm and rotational amplitude 90° ± 3°. The average dose deviation of target dose (centre and peripheral) of TPS dose planning and target motion measurement on 3DCRT with 5 mm, 10 mm and 15 mm were 3.2%, 3.1%, and 1.8% respectively, and dose deviation on IMRT were 3.9%, 2.5%, and 2.8%, while dose deviation on VMAT treatment were 4.2%, 4.6%, and 6.1% respectively. The preliminary result supported the previous work by Mukhlisin. Furthermore, rotational movement of phantom contributed in average of 1.5% compare to translational movement only.Keywords
This publication has 6 references indexed in Scilit:
- Dosimetric effect of uncorrected rotations in lung SBRT with stereotactic imaging guidancePhysica Medica, 2017
- Lung cancer. Radiotherapy in lung cancer: Actual methods and future trendsReports of Practical Oncology and Radiotherapy, 2014
- The Use of the Active Breathing Coordinator Throughout Radical Non–Small-Cell Lung Cancer (NSCLC) RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119Medical Physics, 2009
- The use of a multipurpose phantom for mailed dosimetry checks of therapeutic photon beams: ‘OPERA’ (operational phantom for external radiotherapy audit)Radiotherapy and Oncology, 2002
- Final Results of Phase III Trial in Regionally Advanced Unresectable Non-Small Cell Lung CancerChest, 2000