Prophylactic effect of self-administered pump-driven subcutaneous IgG infusion in patients with antibody deficiency: a triple-blind cross-over study comparing P-IgG levels of 3 g l−1versus 6 g l−1
Authors:
- 1 January 1991
- journal article
- clinical trial
- Published by Wiley in Journal of Internal Medicine
- Vol. 229 (1) , 73-77
Abstract
Eight adult patients with hypoimmunoglobulinaemia were randomly allocated to initiation of low- or high-level IgG-substitution. IgG was administered subcutaneously, at 50 or 150 mg ml-1, 20 ml per infusion, by means of a pocket-portable electric infusion pump. Infusions were given 2 to 4 times weekly for 24 months, with a change of dose regimen after 12 months. The desired plasma IgG levels were reached after a mean lag phase of 3 months (range 1-5 months). The median (and ranges) of the individual mean plasma IgG levels during the ensuing 9-month periods were as follows: high-level period, 6.5 g l-1 (range 6.2-7.8 g l-1); low-level period, 3.2 g l-1 (range 3.0-4.0 g l-1). During the high-level period, compared to the low-level period, there was a significant decrease in the following parameters: 'days in bed at home', 'days missed work' and 'days with fever'. No serious side-effects were observed. It is concluded that a plasma IgG concentration of 6 g l-1 can readily be achieved by subcutaneous IgG substitution, and the prophylactic effect is superior to that obtained with a plasma IgG concentration of 3 g l-1.Keywords
This publication has 4 references indexed in Scilit:
- HIGH-DOSE VERSUS LOW-DOSE INTRAVENOUS IMMUNOGLOBULIN IN HYPOGAMMAGLOBULINAEMIA AND CHRONIC LUNG DISEASEThe Lancet, 1987
- Efficacy of Intravenous Immunoglobulin in Primary Humoral Immunodeficiency DiseaseAnnals of Internal Medicine, 1984
- Immunoglobulin Replacement Therapy by Slow Subcutaneous InfusionAnnals of Internal Medicine, 1980
- Minimization: A new method of assigning patients to treatment and control groupsClinical Pharmacology & Therapeutics, 1974