Accuracy of ADC derived from DWI for differentiating high-grade from low-grade gliomas
Authors:
- De-Qiang LeiDLDe-Qiang Lei
- Ye YuanYYYe Yuan
- Nan-Xiang XiongNXNan-Xiang Xiong
Open Access
- 1 February 2020
- journal article
- review article
- Published by Wolters Kluwer Health in Medicine
- Vol. 99 (8) , e19254
Abstract
Objective: Quantitative apparent diffusion coefficient (ADC) values of diffusion weighted imaging (DWI) could be applied to grade gliomas. This meta-analysis was conducted to assess the accuracy of ADC analysis in differentiating high-grade (HGGs) from low-grade gliomas (LGGs). Methods: PubMed, Cochrane library, Science Direct, and Embase were searched to identify suitable studies up to September 1, 2018. The quality of studies was evaluated by the quality assessment of diagnostic accuracy studies (QUADAS 2). We estimated the pooled sensitivity, specificity, positive and negative likelihood ratios (LR), diagnostic accuracy ratio (DOR) with 95% confidence intervals (CI), and determined the accuracy of the data by using the summary receiver operating characteristic (SROC) and calculating the area under the curve (AUC) to identity the accuracy of ADC analysis in grading gliomas. Results: Eighteen studies including 1172 patients were included and analyzed. The pooled sensitivity, specificity, PLR, NLR, DOR, and AUC with 95% CIs of DWI with b values of 1000 s/mm2 for separating HGGs from LGGs were 0.81 (95% CI 0.75–0.86), 0.87 (95% CI 0.81–0.91), 6.1 (95% CI 4.2–8.9), 0.22 (95% CI 0.17–0.29), 28 (95% CI 17–45), and 0.91 (95% CI 0.88–0.93), respectively. DWI with b values of 3000 s/mm2 showed slightly higher accuracy than that of 1000 (sensitivity 0.80, specificity 0.90 and AUC 0.92). Meta-regression analyses showed that field strengths and b values had significant impacts on diagnostic efficacy. Deeks testing confirmed no significant publication bias in all studies. Conclusions: This meta-analysis suggested that ADC analysis of DWI have high accuracy in differentiating HGGs from LGGs. Standardized methodology is warranted to guide the use of this technique for clinical decision-making.Keywords
Funding Information
- Union Hospital, Tongji Medical College, Huazhong University of Science and Technology (02.03.2017-65)
This publication has 37 references indexed in Scilit:
- Lymphomas and glioblastomas: Differences in the apparent diffusion coefficient evaluated with high b-value diffusion-weighted magnetic resonance imaging at 3 TEuropean Journal of Radiology, 2012
- Measurements of diagnostic examination performance using quantitative apparent diffusion coefficient and proton MR spectroscopic imaging in the preoperative evaluation of tumor grade in cerebral gliomasEuropean Journal of Radiology, 2011
- Diagnostic value of minimum apparent diffusion coefficient values in prediction of neuroepithelial tumor gradingJournal of Magnetic Resonance Imaging, 2010
- Overall survival, prognostic factors, and repeated surgery in a consecutive series of 516 patients with glioblastoma multiformeActa Neurologica Scandinavica, 2010
- Preoperative Grading of Presumptive Low-Grade Astrocytomas on MR Imaging: Diagnostic Value of Minimum Apparent Diffusion CoefficientAmerican Journal of Neuroradiology, 2008
- The 2007 WHO Classification of Tumours of the Central Nervous SystemActa Neuropathologica, 2007
- Imaging Tumor Vascular Heterogeneity and Angiogenesis using Dynamic Contrast-Enhanced Magnetic Resonance ImagingClinical Cancer Research, 2007
- Frameless image-guided stereotactic brain biopsy procedure: diagnostic yield, surgical morbidity, and comparison with the frame-based techniqueJournal of Neurosurgery, 2006
- Independent predictors of morbidity after image-guided stereotactic brain biopsy: a risk assessment of 270 casesJournal of Neurosurgery, 2005
- Basic principles of ROC analysisSeminars in Nuclear Medicine, 1978