Investigation of noise effect on image quality in microwave head imaging systems
Open Access
- 1 February 2015
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Microwaves, Antennas & Propagation
- Vol. 9 (3) , 200-205
Abstract
The effect of noise on the ability to detect strokes in the human head using microwave‐based systems is investigated using both simulations and measurements. The simulations, which are implemented using the full‐wave electromagnetic solver (CST), utilise a realistic numerical head model generated from magnetic resonance imaging slices. On the other hand, the experiments are performed using a wideband microwave system with a frequency range of 1–4 GHz. The experiments use a head phantom consisting of materials that accurately emulate (within 3% of reported properties of human brain tissues) the main tissues found in the human brain. It is shown, in both of the simulations and measurements, that a minimum signal‐to‐noise ratio of around 10 dB is required to accurately detect the presence of a stroke. Below this level, the microwave‐based system either does not detect or falsely indicates the location of the stroke. Based on the presented results, the required microwave power to achieve acceptable detection is well within the recommended safe levels.Keywords
This publication has 19 references indexed in Scilit:
- Instantaneous microwave imaging with time‐domain measurements for breast cancer detectionElectronics Letters, 2013
- Reconstruction Quality and Spectral Content of an Electromagnetic Time-Domain Inversion AlgorithmIEEE Transactions on Biomedical Engineering, 2006
- Multistatic Adaptive Microwave Imaging for Early Breast Cancer DetectionIEEE Transactions on Biomedical Engineering, 2006
- Microwave Imaging Via Adaptive Beamforming Methods for Breast Cancer DetectionJournal of Electromagnetic Waves and Applications, 2006
- Microwave Imaging via Space–Time Beamforming: Experimental Investigation of Tumor Detection in Multilayer Breast PhantomsIEEE Transactions on Microwave Theory and Techniques, 2004
- Numerical investigation of breast tumour detection using multi-static radarElectronics Letters, 2003
- On robust Capon beamforming and diagonal loadingIEEE Transactions on Signal Processing, 2003
- Confocal microwave imaging for breast cancer detection: localization of tumors in three dimensionsIEEE Transactions on Biomedical Engineering, 2002
- SAR distribution and temperature increase in an anatomical model of the human eye exposed to the field radiated by the user antenna in a wireless LANIEEE Transactions on Microwave Theory and Techniques, 1998