Highly Selective and Sensitive Membrane Sensors for Copper(II) Ion Based on a New Benzo‐Substituted Macrocyclic Diamide 6,7,8,9,10‐Hexahydro‐2H‐1,13,4,7,10‐benzodioxatriazacyclopentadecine‐3,11(4H,12H)‐dione
- 22 February 2007
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 19 (5) , 587-596
Abstract
Novel PVC membrane (PME) and coated graphite (CGE) Cu2+‐selective electrodes based on 5,6,7,8,9,10‐hexahydro‐2H‐1,13,4,7,10‐benzodioxatriazacyclopentadecine‐3,11(4H,12H)‐dione are prepared. The electrodes reveal a Nernstian behavior over wide Cu2+ion concentration ranges (1.0×10−7–1.0×10−1 M for PME and 1.0×10−8–1.0×10−1 M for CGE) with very low limits of detection (7.8×10−8 M for PME and 9.1×10−9 M for CGE). The potentiometric responses are independent of the pH of the test solutions in the pH range 2.7–6.2. The proposed electrodes possess very good selectivities for Cu2+over a wide variety of the cations including alkali, alkaline earth, transitions and heavy metal ions. The practical utility of the proposed electrodes have been demonstrated by their use in the study of interactions between copper ions and human growth hormone (hGH) in biological systems, potentiometric titration of copper with EDTA and determination of copper content of a sheep blood serum sample and some other real samples.Keywords
This publication has 55 references indexed in Scilit:
- Selective electrochemical sensor for copper (II) ion based on chelating ionophoresAnalytica Chimica Acta, 2006
- Chelating ionophore based membrane sensors for copper(II) ionsTalanta, 2005
- A novel polymeric membrane electrode for the potentiometric analysis of Cu2+ in drinking waterAnalytica Chimica Acta, 2005
- Polymeric membrane and coated graphite samarium(III)-selective electrodes based on isopropyl 2-[(isopropoxycarbothioyl)disulfanyl]ethanethioateAnalytica Chimica Acta, 2003
- A New PVC-Membrane Electrode Based on a Thia-Substituted Macrocyclic Diamide for Selective Potentiometric Determination of Silver IonBulletin of the Korean Chemical Society, 2002
- Phase Transfer Catalyzed Synthesis of N,N'-Diaryl-1,2-phenylene DioxydiacetamidesSynthetic Communications, 1996
- Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensorsAnalytica Chimica Acta, 1993
- Membrane model for neutral-carrier-based membrane electrodes containing ionic sitesAnalytical Chemistry, 1993
- Synthetic ionophores. Part 8. Amide–ether–amine-containing macrocycles: synthesis, transport and binding of metal cationsJournal of the Chemical Society, Perkin Transactions 1, 1992
- Pyridine-based macrocycles containing N, O, and S and their use as ion-selective electrodes. Crystal structures of 15-aza-6-oxa-3,9-dithiabicyclo[9.3.1]pentadeca-1(15),11,13-triene and (15-aza-6-oxa-3,9-dithiabicyclo[9.3.1]pentadeca-1(15),11,13-triene)dichlorocopper(II)Inorganic Chemistry, 1991