Abstract
In general, the measurement of the main three optical properties (µ a , µ s and g) in turbid media requires a very precise measurement of the total transmission (TT), the total reflection (TR) and the collimated transmission (CT). Furthermore, an inverse algorithm such as inverse adding doubling or inverse Monte-Carlo-simulations is required for the reconstruction of the optical properties. Despite many available methods, the error free measurement of the scattering coefficient or the g-factor still remains challenging. In this study, we present a way to directly calculate the scattering coefficient from the total and collimated transmission. To allow this, it can be shown that T T C T is proportional to e μ s ⋅ d for a wide range of optical properties if the sample is thick enough. Moreover, a set-up is developed and validated to measure the collimated transmission precisely.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (337270237)
This publication has 35 references indexed in Scilit:
- Diffuse optical spectroscopic imaging correlates with final pathological response in breast cancer neoadjuvant chemotherapyPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2011
- Monte Carlo Model of Stricture Formation in Photodynamic Therapy of Normal Pig EsophagusPhotochemistry and Photobiology, 2009
- In vivo optical characterization of human prostate tissue using near-infrared time-resolved spectroscopyJournal of Biomedical Optics, 2007
- Optical properties of normal and cancerous human skin in the visible and near-infrared spectral rangeJournal of Biomedical Optics, 2006
- In vivo determination of optical properties of normal and tumor tissue with white light reflectance and an empirical light transport model during endoscopyJournal of Biomedical Optics, 2005
- Influence of the Scattering Phase Function Approximation on the Optical Properties of Blood Determined from the Integrating Sphere MeasurementsJournal of Biomedical Optics, 1999
- Effects of cryogenic grinding on soft-tissue optical propertiesApplied Optics, 1996
- Error estimation of measuring total interaction coefficients of turbid media using collimated light transmissionPhysics in Medicine & Biology, 1994
- Double-integrating-sphere system for measuring the optical properties of tissueApplied Optics, 1993
- INDIRECT VERSUS DIRECT TECHNIQUES FOR THE MEASUREMENT OF THE OPTICAL PROPERTIES OF TISSUESPhotochemistry and Photobiology, 1987