An ex-vivo and in-vitro dynamic simulator for surgical and transcatheter mitral valve interventions
Open Access
- 8 December 2023
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 19 (3) , 411-421
Abstract
Purpose: Minimally invasive mitral valve surgery (MIMVS) and transcatheter edge-to-edge repair (TEER) are complex procedures used to treat mitral valve (MV) pathologies, but with limited training opportunities available. To enable training, a realistic hemodynamic environment is needed. In this work we aimed to develop and validate a simulator that enables investigation of MV pathologies and their repair by MIMVS and TEER in a hemodynamic setting. Methods: Different MVs were installed in the simulator, and pressure, flow, and transesophageal echocardiographic measurements were obtained. To confirm the simulator’s physiological range, we first installed a biological prosthetic, a mechanical prosthetic, and a competent excised porcine MV. Subsequently, we inserted two porcine MVs—one with induced chordae tendineae rupture and the other with a dilated annulus, along with a patient-specific silicone valve extracted from echocardiography with bi-leaflet prolapse. Finally, TEER and MIMVS procedures were conducted by experts to repair the MVs. Results: Systolic pressures, cardiac outputs, and regurgitations volumes (RVol) with competent MVs were 119 ± 1 mmHg, 4.78 ± 0.16 l min−1, and 5 ± 3 ml respectively, and thus within the physiological range. In contrast, the pathological MVs displayed increased RVols. MIMVS and TEER resulted in a decrease in RVols and mitigated the severity of mitral regurgitation. Conclusion: Ex-vivo modelling of MV pathologies and repair procedures using the described simulator realistically replicated physiological in-vivo conditions. Furthermore, we showed the feasibility of performing MIMVS and TEER at the simulator, also at patient-specific level, thus providing new clinical perspectives in terms of training modalities and personalized planning.Keywords
Funding Information
- Klaus Tschira Stiftung
This publication has 22 references indexed in Scilit:
- Development of a high-fidelity minimally invasive mitral valve surgery simulatorThe Journal of Thoracic and Cardiovascular Surgery, 2019
- Dynamic Patient-Specific Three-Dimensional Simulation of Mitral RepairInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2018
- Relation of Mitral Valve Surgery Volume to Repair Rate, Durability, and SurvivalJACC, 2017
- The Death of Animals in Medical SchoolNew England Journal of Medicine, 2017
- A Novel Left Heart Simulator for the Multi-modality Characterization of Native Mitral Valve Geometry and Fluid MechanicsAnnals of Biomedical Engineering, 2012
- Design conception and experimental setup for in vitro evaluation of mitral prosthetic valves.2011
- Burden of valvular heart diseases: a population-based studyThe Lancet, 2006
- See One, Do One, Teach One: Advanced Technology in Medical EducationAcademic Emergency Medicine, 2004
- A structural basis for the size-related mechanical properties of mitral valve chordae tendineaeJournal of Biomechanics, 2003
- Grading of Mitral Regurgitation by Quantitative Doppler EchocardiographyCirculation, 1997