Refractive index spectroscopy and material dispersion in fused silica glass
Authors:
- Yago ArosaYAYago Arosa
- Raúl de la FuenteRFRaúl de la Fuente
- 28 July 2020
- journal article
- research article
- Published by Optica Publishing Group in Optics Letters
- Vol. 45 (15) , 4268-4271
Abstract
In this study, we aimed to measure material dispersion in fused silica using a low coherence interferometric method. The measurement was carried out quickly and efficiently in a wide spectral range using this method. The refractive index and group index of fused silica were determined by capturing a few interferograms. The material dispersion was modeled using a Sellmeier equation with three resonances. Three different fits were investigated; the most appropriate fit was the one that used both the measured refractive and group indexes to model the dispersion. Second-order dispersion was also quantified, and zero-dispersion wavelength was determined.Keywords
Funding Information
- Ministerio de Economía y Competitividad (MAT2017-89239-C2-1-P)
- European Regional Development Fund (ED431D 2017/06, ED431E2018/08, GRC ED431C 2016/001)
- Secretaria Xeral de Investigación e Desenvolvemento, Xunta de Galicia
This publication has 16 references indexed in Scilit:
- Simultaneous thickness and group index measurement with a single arm low-coherence interferometerOptics Express, 2014
- Measurement of refractive index and thickness of transparent plate by dual-wavelength interferenceOptics Express, 2010
- Measurement method for the refractive index of thick solid and liquid layersApplied Optics, 2009
- Optical constants of silica glass from extreme ultraviolet to far infrared at near room temperatureApplied Optics, 2007
- Direct measurement of dispersion of the group refractive indices of quartz crystal by white-light spectral interferometryOptics Communications, 2007
- Refractive index, optical dispersion, and group velocity of infrared waves in silica glassJournal of Physics and Chemistry of Solids, 2001
- High-precision index measurement in anisotropic crystals using white-light spectral interferometryApplied Physics B, 2000
- Group refractive index measurement of dry and hydrated type I collagen films using optical low-coherence reflectometryJournal of Biomedical Optics, 1996
- Absolute displacement measurements using modulation of the spectrum of white light in a Michelson interferometerApplied Optics, 1989
- Interspecimen Comparison of the Refractive Index of Fused Silica*,†Journal of the Optical Society of America, 1965