Clinical and histologic tissue responses of skin incisions closed with glycomer 631 and lactomer 9–1 using a subcuticular technique in pigs
Open Access
- 24 February 2020
- journal article
- research article
- Published by Springer Nature in BMC Veterinary Research
- Vol. 16 (1) , 1-9
Abstract
Background: Glycomer 631 and lactomer 9–1 are absorbable suture materials indicated for soft tissue approximation in non-infected wounds. Pigs are often used as surgical models in translational research; however, reports of tissue reactions to both suture materials in pigs are limited. The aim of this study was to assess clinical and histologic responses of skin incisions closed with a subcuticular technique using glycomer 631 and lactomer 9–1 in pigs. Results: Skin incisions on 17 pigs were closed with glycomer 631 and lactomer 9–1, and a clinical reactive score (CRS) including erythema, swelling, discharge and dehiscence was calculated on postoperative days 7 and 14. Subcuticular tissue reaction was assessed histologically on postoperative day 14 (the presence of extravascular neutrophils, macrophages, multinucleated giant cells, lymphocytes, fibroblasts, bacterial colonies and the overall severity of the inflammatory response to the suture material), and the cumulative score of the variables was calculated as an aggregate tissue irritation score (ATIS). Tissue samples were examined for suture extrusion and evaluated microbiologically. The clinical reactive score did not differ between the suture materials. Only one ATIS variable, namely the overall severity of the inflammatory response, was lower (p = 0.029) when glycomer 631 was used. Suture extrusion was found in 10/17 of the incisions closed by glycomer 631 and in 7/13 of the incisions closed by lactomer 9–1. Trueperella pyogenes was isolated from the skin and from the area of tissue reaction in six pigs. Conclusions: No difference in CRS between the suture materials was observed, and thus both materials may be used for the subcuticular technique in pigs. Glycomer 631 induced less tissue reaction only in terms of the overall severity of the inflammatory response. Suture extrusion was observed in more than 50% of incisions regardless of the suture material, possibly due to a large amount of suture material in the wound. Trueperella pyogenes was the only pathogen isolated from the tissue surrounding the suture material.Keywords
All Related Versions
Funding Information
- The Slovenian Research and Innovation Agency (P4-0053, P3-0043-0381)
- University Medical Centre Ljubljana (Tertiary Funding)
This publication has 23 references indexed in Scilit:
- Disposition and oral bioavailability of amoxicillin and clavulanic acid in pigsJournal of Veterinary Pharmacology and Therapeutics, 2007
- Experimental Studies in Swine for Measurement of Suture ExtrusionJournal of Long-Term Effects of Medical Implants, 2004
- Surgery: Comparison of three closure methods and two absorbable suture materials for closure of jejunal enterotomy incisions in healthy dogsVeterinary Quarterly, 2001
- Comparative study on biocompatibility and absorption times of three absorbable monofilament suture materials (Polydioxanone, Poliglecaprone 25, Glycomer 631)British Journal of Plastic Surgery, 2000
- Comparison of two suture materials for intradermal skin closure in dogsVeterinary Quarterly, 1997
- Incidence, location and interrelationships between the sites of abscesses recorded in pigs at a bacon factory in Northern IrelandVeterinary Record, 1996
- Subcuticular Sutures and the Rate of Inflammation in Noncontaminated WoundsAnnals of Emergency Medicine, 1995
- Tissue Oxygenation, Anemia, and Perfusion in Relation to Wound Healing in Surgical PatientsAnnals of Surgery, 1991
- Interspecies and Interregional Analysis of the Comparative Histologic Thickness and Laser Doppler Blood Flow Measurements at Five Cutaneous Sites in Nine SpeciesJournal of Investigative Dermatology, 1990
- THE PANNICULUS CARNOSUS IN THE DOMESTIC PICPlastic and Reconstructive Surgery, 1977