An evaluation of a novel instrument for measuring macular pigment optical density: the MPS 9000
- 8 November 2011
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 90 (2) , e90-e97
Abstract
Of the antioxidants found in the human retina, only the macular carotenoid quantities can be estimated noninvasively (albeit in a collective fashion), thus facilitating study of their role in that tissue. The aim of this study was to evaluate concordance between macular pigment optical density (MPOD) values recorded on a commercially available instrument, the MPS 9000, with those of an already validated heterochromatic flicker photometry instrument. Also, we assessed and compared test-retest variability for each instrument. Macular pigment optical density at 0.5 retinal eccentricity was measured using two different heterochromatic flicker photometers, the MPS 9000 and the Macular Densitometer(TM), in 39 healthy subjects. Test-retest variability was evaluated separately for each instrument by taking three readings over a 1-week period in 25 subjects. There was a moderate positive correlation for MPOD at 0.5° of retinal eccentricity between the MPS 9000 and the Macular Densitometer described by the linear equation y = 0.763x + 0.172 (r = 0.68, p < 0.001, r(2) = 0.46); however, a paired-samples t-test showed a significant difference in terms of mean values, with a bias of lower MPOD values being yielded by the MPS 9000 (t = -4.103, p < 0.001). Bland-Altman analysis indicated only moderate agreement between the two instruments, reflected in 95% limits of agreement of 0.1 ± 0.27. Inter-sessional repeatability, expressed as a coefficient of repeatability, ranged from 0.18 to 0.21 [mean (±SD): 0.19 (0.02)] for the MPS 9000 and from 0.11 to 0.12 [mean (±SD): 0.12 (0.01)] for the Macular Densitometer. The results demonstrate that the MPS 9000 consistently yields MPOD readings, which are lower than that found with the Macular Densitometer, and exhibits substantial test-retest variability.Keywords
This publication has 41 references indexed in Scilit:
- Macular pigment optical density measurements: evaluation of a device using heterochromatic flicker photometryEye, 2010
- The repeatability of the MPS 9000 macular pigment screenerBritish Journal of Ophthalmology, 2010
- Augmentation of Macular Pigment Following Supplementation with All Three Macular Carotenoids: An Exploratory StudyCurrent Eye Research, 2010
- The value of measurement of macular carotenoid pigment optical densities and distributions in age-related macular degeneration and other retinal disordersVision Research, 2010
- Spatial Profile of Macular Pigment and Its Relationship to Foveal ArchitectureInvestigative Ophthalmology & Visual Science, 2008
- Estimation of macular pigment optical density in the elderly: Test–retest variability and effect of optical blur in pseudophakic subjectsVision Research, 2007
- Measurement of Macular Pigment Optical Density Using Two Different Heterochromatic Flicker PhotometersCurrent Eye Research, 2007
- Visual Search Across the Life Span.Developmental Psychology, 2004
- Aging and the Speed/Accuracy Relation in Visual Search: Evidence for an Accumulator ModelOptometry and Vision Science, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986