Comparison of Ambu® AuraGain™ laryngeal mask and air-Q™ intubating laryngeal airway for blind tracheal intubation in adults: A randomized controlled trial
Authors:
Open Access
- 1 April 2017
- journal article
- Published by Taylor & Francis in Egyptian Journal of Anaesthesia
- Vol. 33 (2) , 137-140
Abstract
Background: This study has been designed to compare the performance of Ambu® AuraGain™ laryngeal mask with the air-Q™ as a conduit for blind tracheal intubation in adult patients. Methods: In this prospective randomized controlled trial blind endotracheal intubation success rates were compared between Ambu® AuraGain™ and air-Q™ intubating laryngeal airway in 90 adult patients. Patients were randomized in two equal groups: Group Ambu® AuraGain™ (n = 45) and Group air-Q™ (n = 45). Results: Time to insert the laryngeal airway was similar between Ambu® AuraGain™ and air-Q™ (median [IQR] 13[12–14] s versus 14[12–16] s) and in all cases laryngeal mask insertion was possible in first attempt. Intubation success rate at first attempt was significantly higher in air-Q™ group compared to in Ambu® AuraGain™ group (68.9% versus 35.6%; p = 0.002). Overall blind intubation success rate was significantly higher in air-Q™ group in comparison to Ambu® AuraGain™ (80% versus 53.3%; p = 0.007). Intubation time was significantly higher with Ambu® AuraGain™ (p < 0.0001; median difference 4.0 s, 95% CI 2.7, 5.3 s). Blind intubation was significantly easier in air-Q™ group compared to in Ambu® AuraGain™ (42.2% intubation was graded as easy in air-Q™ instead of 22.2% in Ambu® AuraGain™, p = 0.04). Comparison of fibreoptic bronchoscopic glottis view was similar between the two devices (p = 0.07). Reported complications were infrequent and similar between the two devices. Conclusion: We conclude that air-Q™ laryngeal airway is superior to Ambu® AuraGain™ when used as a conduit for blind endotracheal intubation in adult patients. Trial registration: Clinical Trial Registry of India (CTRI/2015/02/005553)Keywords
This publication has 7 references indexed in Scilit:
- Air-Q intubating laryngeal airway: A study of the second generation supraglottic airway deviceIndian Journal of Anaesthesia, 2016
- Comparison of success rate of intubation through Air-Q with ILMA using two different endotracheal tubesIndian Journal of Anaesthesia, 2016
- A randomised comparison of the Ambu ® AuraGain ™ and the LMA ® supreme in infants and childrenAnaesthesia, 2015
- Blind intubation of anaesthetised children with supraglottic airway devices AmbuAura-i and Air-Q cannot be recommendedEuropean Journal of Anaesthesiology, 2015
- CobraPLUS and Cookgas air-Q versus Fastrach for blind endotracheal intubation: a randomised controlled trialEuropean Journal of Anaesthesiology, 2011
- Comparison of blind tracheal intubation through the intubating laryngeal mask airway (LMA Fastrach TM ) and the Air‐Q TMAnaesthesia, 2011
- Difficult Airway Society guidelines for management of the unanticipated difficult intubationAnaesthesia, 2004