Detection of glass particles on bone lesions using SEM-EDS
- 23 May 2017
- journal article
- research article
- Published by Springer Nature in International journal of legal medicine
- Vol. 131 (5) , 1347-1354
Abstract
The problem of identifying the wounding agent in forensic cases is recurrent. Moreover, when several tools are involved, distinguishing the origin of lesions can be difficult. Scanning electron microscopy (SEM)/energy dispersive X-ray analysis (EDS) equipment is increasingly available to the scientific and medical community, and some studies have reported its use in forensic anthropology. However, at our knowledge, no study has reported the use of SEM-EDS in forensic cases involving glass tools, whether in case reports or experiments. We performed an experimental study on human rib fragments, on which we manually created wounds using fragments of window and mirror glass. SEM-EDS was executed on samples without any further preparation on low vacuum mode, then on the same samples after defleshing them completely by boiling them. Window and mirror glass particles were detected on experimental wounds. Both had silica in their spectra, and the opaque side of the mirror contained titanium, allowing for their identification. Boiling and defleshing the bone samples involved a loss of information in terms of the number of wounds detected as positive for glass particles and in the number of glass particles detected, for both window and mirror glass. We suggest the analysis of wounds with suspected glass particles using low vacuum mode and with no defleshment by boiling.Keywords
This publication has 19 references indexed in Scilit:
- Macroscopic and Microscopic Analysis of Knife Stab Wounds on Fleshed and Clothed RibsJournal of Forensic Sciences, 2012
- Analysis of microtraces in invasive traumas using SEM/EDSForensic Science International, 2012
- Scanning Electron Microscopy Analysis of Experimental Bone Hacking Trauma of the MandibleAmerican Journal of Forensic Medicine & Pathology, 2010
- SEM Analysis of Non-Conducting Materials under Low Vacuum ConditionsAdvanced Materials Research, 2010
- Analysis of Gunshot Residue and Associated Materials—A ReviewJournal of Forensic Sciences, 2010
- Identify the injury implements by SEM/EDX and ICP-AESForensic Science International, 2007
- The application of a variable-pressure scanning electron microscope with energy dispersive X-ray microanalyser to the diagnosis of electrocution: a case reportLegal Medicine, 2004
- A biomechanical reconstruction of a wound caused by a glass shard — a case reportForensic Science International, 2001
- Forensic Discrimination of Bottle Glass by Refractive Index Measurement and Analysis of Trace Elements with ICP-MSAnalytical Sciences, 2000
- The Uses of Scanning Electron Microscopy in the Interpretation of Some Examples of Trauma in Human Skeletal Remains1993