Background and Objectives There is no standardized method of measuring the parameters for haemolysis determination of red cell concentrate (RCC). Three haemoglobin quantification methods (automated analyser, Harboe and Drabkin’s) and two methods of haematocrit measurement (automated analyser and microcapillary centrifugation) were evaluated for use with RCC. Materials and Methods Twenty stored RCC were assayed for total haemoglobin, supernatant haemoglobin and haematocrit. Results Drabkin’s and Harboe methods were linear (r2 ≥ 0·995) over 0·015–220 g/l haemoglobin. Overestimation by Drabkin’s increased from 0% at 220 g/l to 137% at 0·015 g/l haemoglobin. Harboe values generally stayed within 6% of expected while haematology analyser values had a maximum 11% underestimation above 10 g/l. Analyser total haemoglobin was significantly lower (202 ± 22 g/l) than Drabkin’s (224 ± 24 g/l) and Harboe (222 ± 22 g/l) values. Haematocrit was greater via the analyser (65·7 ± 5·7%) than with microcapillary centrifugation (59·3 ± 5·7%). Conclusions Harboe and Drabkin’s methods are suitable for measuring total haemoglobin and supernatant haemoglobin in RCC. The analyser gave higher haematocrit values (11% on average) than did microcapillary centrifugation.Keywords
This publication has 17 references indexed in Scilit:
- Implementation of buffy coat platelet component production: comparison to platelet‐rich plasma platelet productionTransfusion, 2008
- Red cell hemolysis during processing and storageAsian Journal of Transfusion Science, 2007
- Interlaboratory comparison of red‐cell ATP, 2,3‐diphosphoglycerate and haemolysis measurementsVox Sanguinis, 2005
- Prestorage leukoreduction and low‐temperature filtration reduce hemolysis of stored red cell concentratesTransfusion, 2004
- A simple spectrophotometric method for the quantification of residual haemoglobin in platelet concentratesVox Sanguinis, 2004
- Red blood cell hemolysis during processingTransfusion Medicine Reviews, 2002
- Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1995) and specifications for international haemiglobinocyanide standard (4th edition).Journal of Clinical Pathology, 1996
- Volume control of erythrocytes during storageTransfusion, 1988
- Rapid method for the estimation of plasma haemoglobin levels.Journal of Clinical Pathology, 1968
- A Method for Determination of Hemoglobin in Plasma by Near-Ultraviolet SpectrophotometryScandinavian Journal of Clinical and Laboratory Investigation, 1959