Abstract
A Fire Safety Ranking System (EB-FSRS) is proposed for assessing the fire safety provisions in existing high-rise nonresidential buildings in Hong Kong. The objective is to investigate how far the fire safety provisions in those existing buildings deviate from the expectation of new codes. Suitable fire safety management can then be worked out in the transition period, based on the scores. Local fire codes were reviewed first to decide what should be the attributes and their weightings. From the reviewing results, three groups of attributes were proposed in the EB-FSRS. These are the passive building construction, active fire protection systems (fire services installation), and key risk parameters, all following the local fire safety requirements. The concept is similar to those equivalent concepts on fire safety parameters of the National Fire Protection Association–Fire Safety Evaluation System (NFPA-FSES). But the EB-FSRS is not a “trade-off” exercise. Thirty-seven old high-rise buildings were rated by studying their architectural features, interior details, and fire safety provisions. Scores under EB-FSES and NFPA-FSES are also compared.Keywords
This publication has 18 references indexed in Scilit:
- A proposed fire safety ranking system for karaoke establishments and its comparison with the NFPA-fire safety evaluation systemBuilding and Environment, 2002
- A Fire Safety Ranking System for Karaoke Establishments in Hong KongJournal of Fire Sciences, 2001
- Implementation of performance-based fire codesFire Safety Journal, 1999
- A proposed fire safety ranking system for old highrise buildings in the Hong Kong Special Administrative RegionFire and Materials, 1999
- Numerical Studies on Recent Large High-Rise Building FireJournal of Architectural Engineering, 1998
- Fire safety codes for Hong Kong: Inadequacy for atrium designBuilding Services Engineering Research & Technology, 1998
- Literature Review of Performance-Based Fire Codes and Design EnvironmentJournal of Fire Protection Engineering, 1998
- Fire models and designFire Safety Journal, 1997
- Prediction of Fire Environment in Apartments Using Zone ModelsJournal of Fire Sciences, 1996
- Aspects of Fires for Factories in Hong KongJournal of Applied Fire Science, 1995