Long-term clinical outcomes of the single-incision technique for implantation of implantable venous access ports via the axillary vein
Authors:
- 23 June 2017
- journal article
- research article
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 18 (4) , 345-351
Abstract
Purpose: To evaluate long-term clinical outcomes and complications of the single-incision technique for implantation of totally implantable venous access ports (TIVAPs) via the axillary vein. Materials and Methods: A total of 932 TIVAPs were placed in 927 patients between May 2012 and October 2014 using a single-incision technique. Patients included 620 men and 307 women with a mean age of 60.0 years. TIVAPs were placed via the left (n = 475) and right (n = 457) axillary veins after making a single oblique vertical incision and medial side pocket without subcutaneous tunneling. We retrospectively reviewed medical records to evaluate status of the patients and TIVAPs, complications, and reasons for explantation. In patients who still had a TIVAP in place, we calculated the duration of TIVAP use from the cut-off day of November 1, 2015. Results: Clinical follow-up was obtained for a total device service period of 311,069 days with a median indwelling time of 467 days (range: 3-1097 days). A total of 37 (4.0%) complications developed. Early complications (n = 4) were one case each of stenosis of the brachiocephalic vein by tumor growth, thrombosis of axillary vein, intravascular migration, and malfunction depending on patient's position. Late complications (n = 33) were suspected catheter-related blood stream infection (n = 23), local infection of the pocket (n = 4), symptomatic stenosis and thrombosis of central vein (n = 4), malfunction by fibrin sleeve (n = 1), and intravascular migration (n = 1). Conclusions: A single-incision technique for TIVAP implantation via the axillary vein seems to be safe with a low risk of complication.Keywords
This publication has 26 references indexed in Scilit:
- A Single-Incision Technique for Placement of Implantable Venous Access Ports via the Axillary VeinJournal of Vascular and Interventional Radiology, 2014
- Totally implantable vascular access devices 30 years after the first procedure. What has changed and what is still unsolved?Supportive Care in Cancer, 2014
- Systematic review: malfunction of totally implantable venous access devices in cancer patientsSupportive Care in Cancer, 2011
- Single-incision Technique for Tunneled Central Venous AccessJournal of Vascular and Interventional Radiology, 2009
- Single-Incision Method for the Placement of an Implantable Chest Port or a Tunneled CatheterJournal of Vascular and Interventional Radiology, 2007
- Surgical technique for totally implantable access ports (TIAP) needs improvement: A multivariate analysis of 400 patientsJournal of Surgical Oncology, 2005
- A prospective randomized trial demonstrating valved implantable ports have fewer complications and lower overall cost than nonvalved implantable portsThe American Journal of Surgery, 2004
- Totally implantable venous-access ports: local problems and extravasation injuryThe Lancet Oncology, 2002
- Central Venous Access: A Primer for the Diagnostic RadiologistAmerican Journal of Roentgenology, 2002
- Implantable catheter system for long-term intravenous chemotherapyJournal of Surgical Oncology, 1989