Percutaneous needle biopsy of lung nodules under CT fluoroscopic guidance with use of the “I-I device”

Authors:
  • TYT Yamagami
    T Yamagami
  • TKT Kato
    T Kato
  • THT Hirota
    T Hirota
  • TMT Matsumoto
    T Matsumoto
  • JSJ Shimada
    J Shimada
  • TNT Nishimura
    T Nishimura

Abstract
The aim of this study is to evaluate the feasibility and safety of CT fluoroscopic-guided needle biopsy with the use of the “I-I device”, which was developed to assist in precisely advancing the needle while avoiding irradiation to the operator's hand. Using the “I-I device” under CT fluoroscopic guidance, 131 percutaneous needle lung biopsies were performed followed by histopathological evaluation. The final diagnosis was confirmed by independent surgical pathological findings or clinical follow-up. The rate of success in obtaining specimens adequate for histopathological analysis was 100% (131/131). For the 104 lesions that we were able to follow up, sensitivity, specificity and accuracy in diagnosing malignancy were 93.8%, 100% and 95.2%, respectively. In 51 lesions for which surgery was performed, the specific cell type was characterized in 98.0% (50/51; malignant, n = 38; benign, n = 12). The specific cell type was precisely diagnosed and confirmed after surgery in 36 malignant lesions and 8 benign l...

This publication has 29 references indexed in Scilit: