Assessing the Knee Extensor’s Rate of Force Development Using a Fixed Handheld Dynamometer: An Inter- and Intrasession Reliability Study
- 1 May 2025
- journal article
- research article
- Published by Human Kinetics in Journal of Sport Rehabilitation
- Vol. 34 (4) , 443-448
Abstract
Context: The rate of force development (RFD), defined as the ability to rapidly generate muscle force, is commonly tested using an electromechanical dynamometer in isometric mode. However, these devices are expensive and not readily available. Therefore, this study aims to evaluate the interrater reliability of a fixed handheld dynamometer to measure the knee extensors’ RFD and provide reference values using the proposed method. Design: This study used a cross-sectional study design. Methods: Using a fixed handheld dynamometer (microFET2) and a 3-dimensional-printed adapter, we evaluated the knee extensor muscles in participants seated at the edge of a treatment bed. Each participant performed a standardized warm-up, followed by 3 maximal isometric knee extension trials. The outcome measures were peak force and early and late phase RFD (0–100 and 0–200 ms, respectively). The study consisted of 3 sessions: Visit one comprised of an initial session (session 1A) followed by a second session (session 1B) after 30 minutes for intrasession reliability; and visit two, conducted on week later, comprised the third session (session 2) for intersession reliability. Results: Fifty-one participants were enrolled in the study. The in-session intraclass correlation coefficient for the early phase RFD was .87 (95% CI, .74–.92) and .91 to .92 (95% CI, .87–.94) for the late phase. The between-session intraclass correlation coefficient for the early phase RFD was .83 to .86 (95% CI, .74–.91) and .87 to .90 (95% CI, .80–.94) for the late phase. Finally, the peak force’s intraclass correlation coefficient was .95 (95% CI, .92–.97) for the in-session and .91 to .92 (95% CI, .86–.95) for the between-session reliability. Conclusions: Our approach provides a reliable, cost-effective, and quick method to evaluate the knee extensor muscles’ RFD and peak force.Keywords
This publication has 22 references indexed in Scilit:
- Osteoarthritis year in review 2019: mechanicsOsteoarthritis and Cartilage, 2020
- Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreementPhysical Therapy in Sport, 2019
- Physiological and methodological aspects of rate of force development assessment in human skeletal muscleClinical Physiology and Functional Imaging, 2017
- Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization deviceMusculoskeletal Science and Practice, 2017
- Contralateral limb deficit after ACL-reconstruction: an analysis of early and late phase of rate of force developmentJournal of Sports Sciences, 2016
- Rate of force development: physiological and methodological considerationsEuropean Journal of Applied Physiology, 2016
- The associations between quadriceps muscle strength, power, and knee joint mechanics in knee osteoarthritis: A cross-sectional studyClinical Biomechanics, 2015
- Reliability of muscle strength measures obtained with a hand‐held dynamometer in an elderly populationClinical Physiology and Functional Imaging, 2015
- Effect of Sampling Rates on the Quantification of Forces, Durations, and Rates of Loading of Simulated Side Posture High-Velocity, Low-Amplitude Lumbar Spine ManipulationJournal of Manipulative and Physiological Therapeutics, 2013
- How to Assess the Reliability of Measurements in RehabilitationAmerican Journal of Physical Medicine & Rehabilitation, 2005