The influence of alternating current frequency on flow related admittance changes of blood: a concept for improvement of impedance cardiography
Authors:
- J W G LangendijkJLJ W G Langendijk
- P M KouwPKP M Kouw
- 1 February 1995
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 16 (1) , 63-69
Abstract
Impedance cardiography is based on admittance changes induced by volume changes of the intrathoracic blood vessels, but also by the longitudinal orientation of red blood cells induced by flow. An experiment was set up to separate these two phenomena and to study their frequency dependence. Admittance changes of flowing blood with variable haematocrit, of a saline solution and of plasma were measured in an in vitro set-up. Four different alternating current frequencies were used: 100 kHz, 5 MHz, 15 MHz and 20 MHz. The measured admittance appeared to be dependent on blood flow: when blood flow increased, admittance in the longitudinal direction increased. This increase was stronger for higher haematocrits, probably due to the longitudinal orientation of the blood cells. At higher frequencies, the orientation effect of the red cells became negligibly small. No frequency or flow dependent admittance change was detected when saline or plasma was used as the perfusate. It is concluded that the orientation effect can be neglected at high frequencies. Impedance cardiography in this range will give more reliable information about volume changes.Keywords
This publication has 8 references indexed in Scilit:
- Electric properties of flowing blood and impedance cardiographyAnnals of Biomedical Engineering, 1989
- Measurement of transcellular fluid shift during haemodialysisMedical & Biological Engineering & Computing, 1989
- Multicomponent noninvasive physiologic monitoring of circulatory functionCritical Care Medicine, 1988
- Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patientsCritical Care Medicine, 1986
- Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedanceCritical Care Medicine, 1986
- Influence of erythrocyte velocity on impedance plethysmographic measurementsMedical & Biological Engineering & Computing, 1978
- Observations on blood flow related electrical impedance changes in rigid tubesPflügers Archiv - European Journal of Physiology, 1976
- THE ELECTRIC RESISTANCE AND CAPACITY OF BLOOD FOR FREQUENCIES BETWEEN 800 AND 4½ MILLION CYCLESJournal of General Physiology, 1925