Effect of TMS coil orientation on the spatial distribution of motor evoked potentials in an intrinsic hand muscle
- 10 August 2017
- journal article
- research article
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 63 (6) , 635-645
Abstract
Previous reports on the relationship between coil orientation and amplitude of motor evoked potential (MEP) in transcranial magnetic stimulation (TMS) did not consider the effect of electrode arrangement. Here we explore this open issue by investigating whether TMS coil orientation affects the amplitude distribution of MEPs recorded from the abductor pollicis brevis (APB) muscle with a bi-dimensional grid of 61 electrodes. Moreover, we test whether conventional mono- and bipolar montages provide representative MEPs compared to those from the grid of electrodes. Our results show that MEPs with the greatest amplitudes were elicited for 45° and 90° coil orientations, i.e. perpendicular to the central sulcus, for all electrode montages. Stimulation with the coil oriented at 135° and 315°, i.e. parallel to the central sulcus, elicited the smallest MEP amplitudes. Additionally, changes in coil orientation did not affect the spatial distribution of MEPs over the muscle extent. It has been shown that conventional electrodes with detection volume encompassing the APB belly may detect representative MEPs for optimal coil orientations. In turn, non-optimal orientations were identified only with the grid of electrodes. High-density electromyography may therefore provide new insights into the effect of coil orientation on MEPs from the APB muscle.Keywords
This publication has 50 references indexed in Scilit:
- Optimal Coil Orientation for Transcranial Magnetic StimulationPLOS ONE, 2013
- Transcranial magnetic brain stimulation: Therapeutic promises and scientific gapsPharmacology & Therapeutics, 2012
- Postural activation of the human medial gastrocnemius muscle: are the muscle units spatially localised?The Journal of Physiology, 2011
- Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and researchClinical Neurophysiology, 2009
- Comparison of navigated and non-navigated transcranial magnetic stimulation for motor cortex mapping, motor threshold and motor evoked potentialsNeuroImage, 2009
- The effect of stimulus intensity on brain responses evoked by transcranial magnetic stimulationHuman Brain Mapping, 2004
- Modeling of surface myoelectric signals. I. Model implementationIEEE Transactions on Biomedical Engineering, 1999
- The thenar musclesSurgical and Radiologic Anatomy, 1992
- Architectural design of the human intrinsic hand musclesThe Journal of Hand Surgery, 1992
- Optimal Focal Transcranial Magnetic Activation of the Human Motor CortexJournal Of Clinical Neurophysiology, 1992