Abstract
Established standards and industrial codes, for interconnecting distributed generation units (DGUs), address voltage and frequency changes, levels and quality of injected power, islanding conditions, and protection. However, these standards and codes do not clearly address the grounding configurations for grid-connected DGUs. One of the challenges related to the grounding configuration for DGUs is the harmonics generated by power electronic converters employed in DGUs. These harmonics can raise the ground potentials and disrupt the function of ground fault protection. This paper develops and tests a frequency-selective grounding configuration for grid-connected DGUs. The developed grounding configuration offers limiting ground potentials and ground fault currents, while imposing negligible impacts on the function of ground fault protective devices. The frequency-selective grounding configuration is designed and tested for two wind energy conversion systems and a photovoltaic system. Test results show that the developed grounding configuration achieves its objectives with negligible impacts on the grounded DGU and its ground fault protection.Keywords
This publication has 19 references indexed in Scilit:
- Impacts of Grounding Configurations on Responses of Ground Protective Relays for DFIG-Based WECSs—Part I: Solid Ground FaultsIEEE Transactions on Industry Applications, 2015
- An Adaptive Prefiltering Method to Improve the Speed/Accuracy Tradeoff of Voltage Sequence Detection Methods Under Adverse Grid ConditionsIEEE Transactions on Industrial Electronics, 2013
- Selection of Distribution Feeders for Implementing Distributed Generation and Renewable Energy ApplicationsIEEE Transactions on Industry Applications, 2013
- Practical Experiences and Mitigation Methods of Harmonics in Wind Power PlantsIEEE Transactions on Industry Applications, 2013
- 13.8-kV Selective High-Resistance Grounding System for a Geothermal Generating Plant—A Case StudyIEEE Transactions on Industry Applications, 2013
- An Effective Semianalytical Method for Simulating Grounding GridsIEEE Transactions on Industry Applications, 2013
- Different Factors Affecting Short Circuit Behavior of a Wind Power PlantIEEE Transactions on Industry Applications, 2012
- Distribution System Analysis and the Future Smart GridIEEE Transactions on Industry Applications, 2011
- A Novel Method of Measuring Inherent Power System Charging CurrentIEEE Transactions on Industry Applications, 2011
- A Single-Stage Three-Phase Grid-Connected Photovoltaic System With Modified MPPT Method and Reactive Power CompensationIEEE Transactions on Energy Conversion, 2007