Failed intramedullary nailing of femur: open reduction and plate augmentation with the nail in situ
- 11 January 2011
- journal article
- Published by Springer Nature in International Orthopaedics
- Vol. 35 (7) , 1089-1092
Abstract
Fourteen patients with aseptic fractures that failed to unite after intramedullary nailing (IMN) of the femur were treated by augmentation of fixation by dynamic compression plate (DCP) with the nail in situ. In six of them that had axial or rotational malalignment, direct reduction of the bone fragments and plating were done. Iliac bone grafting was performed in nine cases, when there were gaps between the fragments and in atrophic non-unions. Patients were followed-up for an average of 26 months. All patients had radiological union in an average of 4.3 months with an improvement in alignment, range of motion and shortening. For failed IMN of the femur, augmentation of fixation by compression plate, with the nail in situ, is a good line of treatment. In cases with malalignment, correction was possible followed by plate augmentation.Keywords
This publication has 15 references indexed in Scilit:
- Use of Locking Compression Plates for Long Bone Nonunions Without Removing Existing Intramedullary Nail: Review of Literature and Our ExperienceJournal of Trauma: Injury, Infection & Critical Care, 2008
- Delayed union of multifragmentary diaphyseal fractures after bridge-plate fixationInternational Orthopaedics, 2008
- Femoral diaphyseal aseptic non-unions: Is there an ideal method of treatment?Injury, 2007
- Exchange Nailing of Ununited FracturesJournal of Bone and Joint Surgery, 2007
- Treatment of the Femoral Shaft Nonunion Occurred after Intramedullary NailingJournal of the Korean Orthopaedic Association, 2007
- Plate augmentation leaving the nail in situ and bone grafting for non-union of femoral shaft fracturesInternational Orthopaedics, 2005
- Augmentative Ilizarov External Fixation After Failure of Diaphyseal Union With Intramedullary NailingJournal of Orthopaedic Trauma, 2002
- Failure of Exchange Reamed Intramedullary Nails for Ununited Femoral Shaft FracturesJournal of Orthopaedic Trauma, 2000
- Success of Exchange Reamed Intramedullary Nailing for Femoral Shaft Nonunion or Delayed UnionJournal of Orthopaedic Trauma, 2000
- Distal Femoral Nonunion: Treatment with a Retrograde Inserted Locked Intramedullary NailJournal of Orthopaedic Trauma, 1995