Changes of the accommodative amplitude and the anterior chamber depth after implantation of an accommodative intraocular lens
- 17 August 2005
- journal article
- research article
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 244 (3) , 322-329
Abstract
Background Modern cataract surgery is interested in recovery of the accommodative power. This investigation aimed at determining pseudophakic accommodation in subjects implanted with the accommodative Human Optics 1 CU intraocular lens after drug-induced ciliary muscle stimulation by measuring the objective refraction and the changes in anterior chamber depth in comparison with a PMMA intraocular lens with rigid haptics. Methods The studied sample involved 30 eyes of 30 patients undergoing cataract surgery due to age-related cataract. Patients were between 50 and 77 years of age (67.71±8.0). No randomization was performed. The 1 CU accommodative intraocular lens and the PMMA intraocular lens were implanted in 15 eyes of patients with an expected visual acuity of at least 0.7. Objective refraction under pilocarpine-stimulated ciliary muscle contraction was determined with a Hartinger coincidence refractometer. The anterior chamber depth was measured with Jäger’s Haag–Streit slit-lamp attachment. The accommodative amplitude and the anterior chamber flattening were calculated from the measured values. Results Twelve weeks after surgery the average accommodative amplitude in eyes with a 1 CU intraocular lens calculated from the refractive change under drug-induced stimulation was 0.48±0.36 D (with a maximum of 1.25 D). The measured change of anterior chamber depth under drug-induced stimulation was 0.3±0.32 mm (at a maximum of 0.9 mm). In the reference group with PMMA lenses, the mean accommodative amplitude derived from the refractive changes under drug-induced stimulation was 0.34±0.27 D (at a maximum of 0.85 D). The measured change in anterior chamber depth under drug-induced stimulation was 0.18±0.09 mm (at a maximum of 0.31 mm). No statistically significant differences were found between the two groups of lenses concerning change in anterior chamber depth and accommodative amplitude. Conclusions This investigations indicate a mean anterior 1 CU shift of only 0.32 mm and a maximum of 0.9 mm. The accommodative amplitudes measured with the Hartinger coincidence refractometer (mean value 0.47 D) correspond to these values. Similar conclusions may be drawn from existing investigative results of the reference group, which are on the same order of magnitude as those of the 1 CU group. Objective accommodation measurements are needed to evaluate commercially available accommodative intraocular lenses in a scientifically satisfactory manner. Objectively measurable parameters include changes of the anterior chamber depth as well as refraction, as determined for instance by coincidence refractometry and streak retinoscopy. Future studies should also consider the IOL properties, astigmatism, and pupillary diameter. This is the only way to identify pseudoaccommodation and a decisive factor for further development of accommodative artificial lenses.Keywords
This publication has 31 references indexed in Scilit:
- Polymer Refilling of Presbyopic Human Lenses In Vitro Restores the Ability to Undergo Accommodative ChangesInvestigative Ophthalmology & Visual Science, 2003
- A prospective comparative study of the amo array zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lensOphthalmology, 1999
- Scleral expansion surgery does not restore accommodation in human presbyopiaOphthalmology, 1999
- Amplitudes of Accommodation of Primate Lenses Refilled With Two Types of Inflatable Endocapsular BalloonsArchives of Ophthalmology (1950), 1993
- Diffractive multifocal intraocular lens implants for unilateral cataracts in prepresbyopic patients.British Journal of Ophthalmology, 1992
- Diffraktive multifokale Intraokularlinsen - Eine prospektive klinische StudieKlinische Monatsblätter für Augenheilkunde, 1990
- Pseudophakic accommodation? A study of the stability of capsular bag supported, one piece, rigid tripod, or soft flexible implants.British Journal of Ophthalmology, 1990
- Phaco-Ersatz: Cataract surgery designed to preserve accommodationGraefe's Archive for Clinical and Experimental Ophthalmology, 1986
- Myopic astigmatism a substitute for accommodation in pseudophakiaDocumenta Ophthalmologica, 1981
- STUDIES WITH IMPEDANCE CYCLOGRAPHY ON HUMAN OCULAR ACCOMMODATION AT DIFFERENT AGESActa Ophthalmologica, 1969