Breath selection methods for compact mass spectrometry breath analysis
- 30 September 2019
- journal article
- research article
- Published by IOP Publishing in Journal of Breath Research
- Vol. 13 (4) , 046013
Abstract
Compact mass spectrometry (CMS) is a versatile and transportable analytical instrument that has the potential to be used in clinical settings to quickly and non-invasively detect a wide range of relevant conditions from breath samples. The purpose of this study is to optimise data preprocessing protocols by three proposed methods of breath sampling, using the CMS. It also lays out a general framework for which data processing methods can be evaluated. Methods. This paper considers data from three previous studies, each using a different breath sampling method. These include a peppermint washout study using continuous breath sampling with a purified air source, an exercise study using continuous breath sampling with an ambient air source, and a single breath sampling study with an ambient air source. For each dataset, different breath selection (data preprocessing) methods were compared and benchmarked according to predictive performance on a validation set and quantitative reliability of m / z bin intensity measurements. Results. For both continuous methods, the best breath selection method improved the predictive model compared to no preselection, as measured by the 95% CI range for Youden’s index, from 0.68–0.86 to 0.86–0.97 for the exercise study and 0.69–0.82 to 1.00–1.00 for the peppermint study. The reliability of intensity measurements for both datasets (as measured by median relative standard deviation (RSD)), was improved slightly by the best selection method compared to no preselection, from 18% to 14% for the exercise study and 7%–5% for the peppermint study. For the single breath samples, all the models resulted in perfect prediction, with a 95% CI range for Youden’s index of 1.00–1.00. The reliability of the proposed method was 38%. Conclusion. The method of selecting exhaled breath from CMS data can affect the reliability of the measurement and the ability to distinguish between breath samples taken under different conditions. The application of appropriate data processing methods can improve the quality of the data and results obtained from CMS. The methods presented will enable untargeted analysis of breath VOCs using CMS to be performed.Keywords
This publication has 21 references indexed in Scilit:
- Continuous Real Time Breath Gas Monitoring in the Clinical Environment by Proton-Transfer-Reaction-Time-of-Flight-Mass SpectrometryAnalytical Chemistry, 2013
- Acetone Response with Exercise Intensity2012
- Phase-resolved real-time breath analysis during exercise by means of smart processing of PTR-MS dataAnalytical and Bioanalytical Chemistry, 2011
- Multivariate methods in metabolomics – from pre-processing to dimension reduction and statistical analysisTrAC Trends in Analytical Chemistry, 2011
- Determination of aldehydes in exhaled breath of patients with lung cancer by means of on-fiber-derivatisation SPME–GC/MSJournal of Chromatography B, 2010
- OpenChrom: a cross-platform open source software for the mass spectrometric analysis of chromatographic dataBMC Bioinformatics, 2010
- A profile of volatile organic compounds in breath discriminates COPD patients from controlsRespiratory Medicine, 2010
- Isoprene and acetone concentration profiles during exercise on an ergometerJournal of Breath Research, 2009
- Lung cancer detection by proton transfer reaction mass-spectrometric analysis of human breath gasInternational Journal of Mass Spectrometry, 2007
- Mass spectrometric profile of exhaled breath—field study by PTR-MSRespiratory Physiology & Neurobiology, 2005