Abstract
Background: A significant proportion of the radiation dose from a PET-CT examination is dependent on the CT protocol, which should be optimised for clinical purposes. Matching protocols on different scanners within an imaging centre is important for the consistency of image quality and dose. This paper describes our experience translating low-dose CT protocols between scanner models utilising different automatic exposure control (AEC) methods and reconstruction algorithms. Methods: The scanners investigated were a newly installed Siemens Biograph mCT PET with 64-slice SOMATOM Definition AS CT using sinogram affirmed iterative reconstruction (SAFIRE) and two GE Discovery 710 PET scanners with 128-slice Optima 660 CT using adaptive statistical reconstruction (ASiR). Following exploratory phantom work, 33 adult patients of various sizes were scanned using the Siemens scanner and matched to patients scanned using our established GE protocol to give 33 patient pairs. A comparison of volumetric CT dose index (CTDIvol) and image noise within these patient pairs informed optimisation, specifically for obese patients. Another matched patient study containing 27 patient pairs was used to confirm protocol matching. Size-specific dose estimates (SSDEs) were calculated for patients in the second cohort. With the acquisition protocol for the Siemens scanner determined, clinicians visually graded the images to identify optimal reconstruction parameters. Results: In the first matched patient study, the mean percentage difference in CTDIvol for Siemens compared to GE was − 10.7% (range − 41.7 to 50.1%), and the mean percentage difference in noise measured in the patients’ liver was 7.6% (range − 31.0 to 76.8%). In the second matched patient study, the mean percentage difference in CTDIvol for Siemens compared to GE was − 20.5% (range − 43.1 to 1.9%), and the mean percentage difference in noise was 19.8% (range − 27.0 to 146.8%). For these patients, the mean SSDEs for patients scanned on the Siemens and GE scanners were 3.27 (range 2.83 to 4.22) mGy and 4.09 (range 2.81 to 4.82) mGy, respectively. The analysis of the visual grading study indicated no preference for any of the SAFIRE strengths. Conclusions: Given the different implementations of acquisition parameters and reconstruction algorithms between vendors, careful consideration is required to ensure optimisation and standardisation of protocols.Keywords
Funding Information
- Wellcome Trust (WT 203148/Z/16/Z)
This publication has 32 references indexed in Scilit:
- Accuracy of CT-based attenuation correction in PET/CT bone imagingPhysics in Medicine & Biology, 2012
- Establishment of a UK-wide network to facilitate the acquisition of quality assured FDG–PET data for clinical trials in lymphomaAnnals of Oncology, 2010
- Automatic exposure control in computed tomography – an evaluation of systems from different manufacturersActa Radiologica, 2010
- Image Gently: Ten Steps You Can Take to Optimize Image Quality and Lower CT Dose for Pediatric PatientsAmerican Journal of Roentgenology, 2010
- Automatic exposure control in pediatric and adult multidetector CT examinations: A phantom study on dose reduction and image qualityMedical Physics, 2008
- Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluationBritish Journal of Radiology, 2007
- Comparison of Angular and Combined Automatic Tube Current Modulation Techniques with Constant Tube Current CT of the Abdomen and PelvisAmerican Journal of Roentgenology, 2006
- Computed Tomography Radiation Dose Optimization: Scanning Protocols and Clinical Applications of Automatic Exposure ControlCurrent Problems in Diagnostic Radiology, 2005
- Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulationEuropean Radiology, 2004