Photo-induced Fluorescence of Fluometuron in a Continuous-flow Multicommutation Assembly
- 13 December 2006
- journal article
- Published by Springer Nature in Journal of Fluorescence
- Vol. 17 (1) , 29-36
Abstract
This paper deals with the photo-induced fluorimetric determination of the herbicide Fluometuron with the aid of a continuous-flow assembly of the emergent and new methodology known as Multicommutation which was provided with an on-line photoreactor. Maximum fluorescence intensity was observed at basic pH solutions, 1×10−4 mol l−1 NaOH, after 1.4 min of irradiation and being the maximum at λexc 247.0 nm and λem 325.0 nm. The influence of different experimental parameters either chemical (pH, surfactants presence, solvent polarity and temperature) or hydrodynamic (time of photo-degradation, size and number of different segments and flow-rate) was tested. The linear dynamic range was from 0.01 to 4.0 mg l−1 of Fluometuron; the inter-day reproducibility (as R.S.D.) of the slope was 0.001% and 1.7% from the peaks intra-day reproducibility. A large series of potential interferents was studied and finally the method was applied to human urine, soil, formulation and water samples.Keywords
This publication has 24 references indexed in Scilit:
- Simultaneous determination of phenyl- and sulfonylurea herbicides in water by solid-phase extraction and liquid chromatography with UV diode array or mass spectrometric detectionAnalytica Chimica Acta, 2004
- Sensitive analyses of agricultural chemicals by capillary electrochromatographyJournal of Separation Science, 2003
- Analysis of phenylurea herbicides from plants by GC/MSTalanta, 2002
- Determination of phenylurea herbicides in drinking waterJPC – Journal of Planar Chromatography – Modern TLC, 2002
- Comparison of automated on-line solid-phase extraction followed by liquid chromatography–mass spectrometry with atmospheric pressure chemical ionization and particle beam mass spectrometry for the determination of a priority group of pesticides in environmental watersJournal of Chromatography A, 1998
- Trace Level Pesticide Detections in Arkansas Surface WatersEnvironmental Science & Technology, 1997
- On-line preconcentration and liquid chromatographic analysis of phenylurea pesticides in environmental water using a silica-based immunosorbentAnalytica Chimica Acta, 1995
- Simultaneous fluometuron and norflurazon analysis in soil extracts and leachatesCommunications in Soil Science and Plant Analysis, 1995
- Supercritical carbon dioxide fluid extraction of fluometuron herbicide from soilJournal of Agricultural and Food Chemistry, 1993
- Simplex optimization of analytical chemical methodsAnalytical Chemistry, 1974