Einthoven and Precordial Lead Accuracy of Smartwatch-Acquired Electrocardiographs: A Review of the Literature
Author:
- 1 January 2020
- journal article
- review article
- Published by SAGE Publications in Australasian Journal of Paramedicine
- Vol. 17, 1-11
Abstract
Introduction: This review aims to summarise the literature regarding the ability of commercial smartwatch products to produce an electrocardiograph of diagnostic quality for interpreting Einthoven and precordial leads. Methods: PubMed, Embase, MEDLINE Complete, Web of Science, and Scopus were systematically searched. Articles were screened by a sole investigator against the inclusion criteria – first by title, then abstract, then full text. The reference lists of included articles were also screened. The inclusion criteria were: discussion of smartwatch-acquired tracing of Einthoven or precordial lead accuracy, and demonstrating sufficient rigor when undergoing critical appraisal using the Joanna Briggs Institute evaluation tools. A synopsis of results was provided in a summary of information table. Results: Twelve articles were identified for inclusion, nine of which had physician (cardiology or emergency specialty) evaluation of tracings, one of which had statistical comparison of wave duration and amplitude, and two of which were expert commentary. Only evaluations of Apple Watch products were discovered during the literature search. All leads in all studies were considered suitable for interpretation, with no clinically significant differences. Four studies found that 100% of patients were able to accurately use a smartwatch as an electrocardiogram after a brief tutorial. Conclusion: The current early evidence, based largely on visual evaluations by cardiologists during the previous year, suggests that electrocardiograph abnormality recorded by this technology is sufficiently precise to be presumed accurate until proven otherwise.Keywords
This publication has 36 references indexed in Scilit:
- Improving risk stratification in patients with chest pain: the Erlanger HEARTS3 scoreThe American Journal of Emergency Medicine, 2012
- A Comparative Analysis of Three Online Appraisal Instruments’ Ability to Assess Validity in Qualitative ResearchQualitative Health Research, 2010
- What is lost when searching only one literature database for articles relevant to injury prevention and safety promotion?Injury Prevention, 2008
- Proximal placement of limb electrodes: a potential solution for acquiring standard electrocardiogram waveforms from monitoring electrode positionsJournal of Electrocardiology, 2008
- Recommendations for the Standardization and Interpretation of the ElectrocardiogramCirculation, 2007
- Comparison of EASI-derived 12-lead electrocardiograms versus paramedic-acquired 12-lead electrocardiograms using Mason-Likar limb lead configuration in patients with chest painJournal of Electrocardiology, 2006
- Comparison of digitized ECGs simultaneously recorded with CR and V leadsJournal of Electrocardiology, 1995
- CR Leads in Cardiac EmergenciesChest, 1991
- How Far Does the Situation of the Indifferent Electrode Influence the Electrocardiographic Unipolar Chest Leads?Cardiology, 1939
- On the use of chest leads in clinical electrocardiographyAmerican Heart Journal, 1935