To compare two prostheses for use in acute abdominal wall replacement in the presence and absence of peritonitis. Forty male Sprague-Dawley rats underwent full-thickness removal of a 2 × 3 cm portion of their anterior abdominal wall. Twenty rats had intraperitoneal contamination with stool slurry. Ten rats in each group (contaminated and noncontaminated) had a 2 × 3 cm piece of Gore-Tex dual-mesh expanded polytetrafluoroethylene (PTFE) sewn full-thickness to cover the abdominal wall defect. The remaining 10 rats in each group had replacement with a 2 × 3 cm piece of Dexon polyglycolic acid mesh (PGA). The rats were then awakened and returned to their cages. Rats were humanely killed at the end of a 3-week observation period or at the time of fistula formation or evisceration. At necropsy, the density of intra-abdominal adhesions was graded on a scale of 0 to 3, and the extent of reepithelialization was noted. Results were analyzed with the Student's t test or Fisher's exact method of χ2 test as indicated. Nineteen PTFE rats and 10 PGA rats survived the observation period, The PTFE rats had significantly fewer adhesions (0.10 ± 0.30 vs. 1.27 ± 1.49, p < 0.005) and significantly more reepithelialization of their wounds (78.2 ± 23.4% vs. 43.6 ± 50.4%, p < 0.05) than the PGA rats. Evisceration and fistula formation occurred more frequently in the PGA group. The mortality in the PTFE rats was significantly less than the PGA rats (5% vs. 50%, p < 0.001.) Notably, the contaminated PGA rats had a significantly higher mortality (90%, p < 0.001) than any of the other subgroups. PTFE is superior to PGA as a replacement prosthesis for acute abdominal wall defects. There are significantly fewer adhesions, improved epithelialization of the wound, and less morbidity and mortality when PTFE is used. This finding is especially true in the presence of intraperitoneal fecal soilage.Keywords
This publication has 17 references indexed in Scilit:
- Abdominal Wall Reconstruction After Temporary Abdominal Wall Closure in Trauma PatientsSouthern Medical Journal, 1996
- Temporary Intravenous Bag Silo Closure in Severe Abdominal TraumaThe Journal of Trauma: Injury, Infection, and Critical Care, 1996
- Esmarch Closure of Laparotomy Incisions in Unstable Trauma PatientsThe Journal of Trauma: Injury, Infection, and Critical Care, 1995
- Planned Ventral Hernia Staged Management for Acute Abdominal Wall DefectsAnnals of Surgery, 1994
- Small-Bowel Perforation Complicating the Open Treatment of Generalized PeritonitisArchives of Surgery, 1989
- Adhesion formation and peritoneal healing on prosthetic materialsClinical Materials, 1988
- Repair of Large Abdominal Wall Defects with Expanded Polytetrafluoroethylene (PTFE)Annals of Surgery, 1987
- Comparison of Prosthetic Materials for Abdominal Wall Reconstruction in the Presence of Contamination and InfectionAnnals of Surgery, 1985
- Emergency Abdominal Wall Reconstruction with Polypropylene MeshAnnals of Surgery, 1981
- Management of Acute Full-thickness Losses of the Abdominal WallAnnals of Surgery, 1981