Bacterial contamination and antimicrobial susceptibility patterns of intensive care units medical equipment and inanimate surfaces at Ayder Comprehensive Specialized Hospital, Mekelle, Northern Ethiopia
Open Access
- 23 September 2019
- journal article
- research article
- Published by Springer Nature in BMC Research Notes
- Vol. 12 (1) , 1-8
Abstract
Objective: To determine bacterial contaminants and their antimicrobial susceptibility patterns from medical equipment and inanimate surfaces.Results: Of 130 swabs, 115 (88.5%) swabs were culture positive, of which contaminated medical equipment and inanimate surfaces account 70 (83.3%) and 45 (97.8%), respectively. All the swabs collected from sphygmomanometer, bedside table, computer and computer standing tables were 100% contaminated with bacteria. From the culture-positive swabs, a total of 171 bacterial isolates were identified, out of which 117 (68.4%) and 54 (31.6%) isolates were gram-positive and gram-negative, respectively. Most isolates (82%) were resistant to ampicillin and 13%, 8.6%, and 14% was observed in ciprofloxacin, gentamicin, and tetracycline respectively. Multi-drug resistant was observed inEscherichia coli(72.7%) andStaphylococcus aureus(58.7%).Keywords
All Related Versions
This publication has 18 references indexed in Scilit:
- Bacterial contamination, bacterial profile and antimicrobial susceptibility pattern of isolates from stethoscopes at Jimma University Specialized HospitalAnnals of Clinical Microbiology and Antimicrobials, 2013
- Risk of acquiring multidrug-resistant Gram-negative bacilli from prior room occupants in the intensive care unitClinical Microbiology and Infection, 2011
- International Study of the Prevalence and Outcomes of Infection in Intensive Care UnitsJAMA, 2009
- Should we Recommend Stethoscope Disinfection Before Daily Usage as an Infection Control Rule?The Open Infectious Diseases Journal, 2009
- Blood pressure cuffs and pulse oximeter sensors: A potential source of cross-contaminationAustralasian Emergency Nursing Journal, 2009
- Contamination of equipment in emergency settings: An exploratory study with a targeted automated interventionAnnals of Surgical Innovation and Research, 2009
- Retrospective analysis of nosocomial infections in the intensive care unit of a tertiary hospital in China during 2003 and 2007BMC Infectious Diseases, 2009
- The stethoscope as a vector of infectious diseases in the paediatric divisionActa Paediatrica, 2008
- Infection control as a major World Health Organization priority for developing countriesJournal of Hospital Infection, 2008
- Blood Pressure Cuff as a Potential Vector of Pathogenic Microorganisms A Prospective Study in a Teaching HospitalInfection Control & Hospital Epidemiology, 2006