Efficacy of 532-nm Nd: YAG Fractional Picosecond Laser with 9 mm High Coverage Handpiece Micro Lens Array in the Treatment of Facial Partial Unilateral Lentiginosis: A Case Report
- 27 July 2024
- journal article
- research article
- Published by Maad Rayan Publishing Company in Journal of lasers in medical sciences
- Vol. 15, e24
Abstract
Introduction: Facial partial unilateral lentiginosis (PUL) is an infrequent skin pigmentation disorder characterized by multiple lentigines. Despite the availability of various treatment modalities, there is no standard treatment for PUL. This study reports a successful treatment of facial PUL in a female patient using a novel 532-nm Nd:YAG fractional picosecond laser (FPL). Case Report: The patient underwent four treatment sessions at four-week intervals. The treatments were administered using a 9 mm high coverage handpiece micro lens array (MLA), with a fluence of 0.2–0.4 J/cm², a frequency of 2 Hz for 2-3 passes, and approximately 10% overlap. The treatment was well-tolerated by the patient, with significant improvement in pigmentation and no significant side effects observed. The outcomes confirmed the efficacy of the 532-nm Nd:YAG FPL in treating facial PUL. Conclusion: The 532-nm Nd:YAG FPL appears to be an effective and well-tolerated treatment for facial PUL, offering significant improvement in pigmentation without notable side effects.Keywords
This publication has 19 references indexed in Scilit:
- Serial change in laser‐induced optical breakdown by 1064‐nm Nd:YAG picosecond laserPhotodermatology, Photoimmunology & Photomedicine, 2019
- Picosecond 532 nm Neodymium-Doped Yttrium Aluminium Garnet Laser for the Treatment of Solar Lentigines in Darker Skin Types: Safety and EfficacyDermatologic Surgery, 2017
- Split lesion randomized comparative study between long pulsed Nd:YAG laser 532 and 1,064 nm in treatment of facial port‐wine stainLasers in Surgery and Medicine, 2016
- Partial unilateral lentiginosis treated with alexandrite Q-switched laser: Case report and review of the literatureJournal of Cosmetic and Laser Therapy, 2013
- Low-Fluence Q-Switched 1,064-nm Neodymium-Doped Yttrium Aluminum Garnet Laser for the Treatment of Facial Partial Unilateral Lentiginosis in KoreansDermatologic Surgery, 2012
- Punctate Leucoderma After 1,064-nm Q-Switched Neodymium-Doped Yttrium Aluminum Garnet Laser with Low-Fluence TherapyDermatologic Surgery, 2010
- A low fluence Q-switched Nd:YAG laser modifies the 3D structure of melanocyte and ultrastructure of melanosome by subcellular-selective photothermolysisJournal of Electron Microscopy, 2010
- Partial unilateral lentiginosis with ipsilateral ocular nevusJournal of the European Academy of Dermatology and Venereology, 2006
- Lentigo.2001
- Partial unilateral lentiginosis with ocular involvementJournal of the American Academy of Dermatology, 2001