Evaluation of Impression Accuracy for Implant at Various Angulations
Authors:
- 1 April 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 19 (2) , 167-174
Abstract
Purpose: The purpose of this study was to compare 2 splinted impression transfer techniques for implant-supported prostheses. Materials: A metal matrix (control) with 4 implants was used. The implants were positioned at 90, 80, 75, and 65 degrees in relation to the surface of the matrix. Squared impression copings were splinted with self-curing acrylic resin in group 1 (n = 10) and with condensation silicone in group 2 (n = 10). A computer software was used to measure the implants/analogs inclinations. Data were analyzed by 2-way analysis of variance and Tukey test (alpha 0.05) nor from group 2 (P > 0.05) regardless implant/analog inclinations. Considering implant/analog inclinations, both techniques did not differ from control group (P > 0.05), except for 75 degrees implant/analog inclinations (P < 0.05). Conclusion: The results suggest that condensation silicone may not be used as an alternative splinting material. Furthermore, implant inclination may affect master cast accuracy. (Implant Dent 2010;19:167-174)Keywords
This publication has 20 references indexed in Scilit:
- Cementable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention studyClinical Oral Implants Research, 2007
- Evaluation of Transfer Impressions for Osseointegrated Implants at Various AngulationsImplant Dentistry, 2004
- Fit of implant frameworks: An in vitro comparison between two fabrication techniquesThe Journal of Prosthetic Dentistry, 2003
- An in vitro study on compensation of mismatch of screw versus cement‐retained implant supported fixed prosthesesClinical Oral Implants Research, 2000
- Evaluation of impression accuracy for osseointegrated implant supported superstructuresThe Journal of Prosthetic Dentistry, 2000
- In vitro comparison of master cast accuracy for single-tooth implant replacementThe Journal of Prosthetic Dentistry, 2000
- A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant systemThe Journal of Prosthetic Dentistry, 1997
- An in vivo quantitative analysis of the fit of Nobel Biocare implant superstructuresJournal of Oral Rehabilitation, 1996
- Measuring fit at the implant prosthodontic interfaceThe Journal of Prosthetic Dentistry, 1996
- A 15-year study of osseointegrated implants in the treatment of the edentulous jawInternational Journal of Oral Surgery, 1981