Abstract
A method of computing megavoltage dose distributions using an empirical mathematical model is described. The dose at a point in a medium is calculated as the product of a central axis percentage depth dose, a crossplot factor and a wedge factor. For a given set of conditions (i.e. type of machine, source-skin distance and wedge) 16 parameters are required to calculate the values of the three factors and hence the dose at any point. These parameters can be obtained from a relatively small number of experimental measurements. Dose distributions from a variety of different treatment machines have been computed by the method, and some comparisons of the calculated and measured doses have been made using "Goodness of Fit" score values. These show that the use of the method as a basis for computer treatment planning should be clinically acceptable.Keywords
This publication has 6 references indexed in Scilit:
- Extending the general field equation to fit the dose distributions of a variety of therapy unitsBritish Journal of Radiology, 1973
- A model simulating photon transport in a finite mediumMathematical Biosciences, 1971
- A general expression for megavoltage central axis depth dosesBritish Journal of Radiology, 1970
- Calculation of percentage depth dose in regions of build-upBritish Journal of Radiology, 1969
- CorrespondenceBritish Journal of Radiology, 1966
- The Computation of Two and Three Dimensional Dose Distributions in Cobalt 60 TeletherapyBritish Journal of Radiology, 1965