Comparing ion‐pairing reagents and counter anions for ion‐pair reversed‐phase liquid chromatography/electrospray ionization mass spectrometry analysis of synthetic oligonucleotides
Author:
- 3 November 2015
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 29 (24) , 2402-2410
Abstract
Rationale: Ion‐pair reversed‐phase liquid chromatography/electrospray ionization mass spectrometry (IP‐RP‐LC/ESI‐MS) has been widely used for the quality control of oligonucleotides. However, researchers are still looking to improve mobile phase systems for IP‐RP‐LC/ESI‐MS analysis of oligonucleotides. This study compared the performance of six ion‐pairing reagents with three different counter anions for IP‐RP‐LC/ESI‐MS analysis of oligonucleotides. Methods: The study was performed using a Waters ultra‐performance liquid chromatography (UPLC®) system coupled to a Waters LCT Premier XE mass spectrometer by using a UPLC® OST column (2.1 mm × 100 mm, 1.7 µm). Buffer systems containing acetate, bicarbonate, and hexafluoroisopropanolate salts of six ion‐pairing reagents (triethylamine, tripropylamine, hexylamine, N,N ‐dimethylbutylamine, dibutylamine, N,N ‐diisopropylethylamine), respectively, were optimized for IP‐RP‐LC/ESI‐MS analysis of oligonucleotides, and then the optimized conditions were applied for the separation of oligonucleotides. Results: Counter anions definitely play a role in IP‐RP‐LC/ESI‐MS analysis of oligonucleotides. Buffer containing 30 mM diisopropylethylamine and 200 mM hexafluoroisopropanol provided the highest separation of unmodified heterogeneous oligonucleotides, but tripropylammonium hexafluoroisopropanolate achieved the most enhanced separation of sequence isomers. However, triethylammonium acetate and bicarbonate had equally the highest separation for positional isomers. Conclusions: IP‐RP‐LC/ESI‐MS separation of oligonucleotides is mainly sequence dependent, but it is also dependent on both the type of ion‐pairing reagent and counter anion present in the mobile phase. Copyright © 2015 John Wiley & Sons, Ltd.Keywords
This publication has 42 references indexed in Scilit:
- Analysis of oligonucleotides by hydrophilic interaction liquid chromatography coupled to negative ion electrospray ionization mass spectrometryJournal of Chromatography A, 2011
- Bioanalysis of an oligonucleotide and its metabolites by liquid chromatography–tandem mass spectrometryJournal of Pharmaceutical and Biomedical Analysis, 2010
- An Improved Ion-Pair Reversed Phase LC Method for Analysis of Major Impurities of Phosphorothioate Oligonucleotide CantideChromatographia, 2010
- Rapid, nondenaturing RNA purification using weak anion-exchange fast performance liquid chromatographyRNA, 2010
- A statistical learning approach to the modeling of chromatographic retention of oligonucleotides incorporating sequence and secondary structure dataNucleic Acids Research, 2007
- Structure–Activity Relationships in Chromatography: Retention Prediction of Oligonucleotides with Support Vector RegressionAngewandte Chemie International Edition, 2006
- Liquid chromatography mass spectrometry of antisense oligonucleotidesBioorganic & Medicinal Chemistry Letters, 1995
- Principles and methods for the analysis and purification of synthetic deoxyribonucleotides by high-performance liquid chromatographyMolecular Biotechnology, 1995
- The Surface Tension of Mixtures of Methanol, Acetonitrile, Tetrahydrofuran, Isopropanol, Tertiary Butanol and Dimethyl-Sulfoxide with Water at 25°CJournal of Liquid Chromatography, 1987
- The Solubility of Carbon Dioxide in Water at Various Temperatures from 12 to 40° and at Pressures to 500 Atmospheres. Critical Phenomena*Journal of the American Chemical Society, 1940