Implantation of Stereoelectroencephalography Electrodes: A Systematic Review
- 1 December 2016
- journal article
- review article
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 33 (6) , 490-502
Abstract
Background: Stereoelectroencephalography (SEEG) was developed by Talairach and Bancaud in Paris in the late 1950s. Subsequently, the Talairach methodology was adopted at a number of additional centers in Europe and Canada. Technical aspects remained essentially unchanged for the following 30 years. Only in the last two decades, because of advancements in image-guided surgery systems, robotics, and computer-aided planning, use of SEEG has become more widespread, and reports describing these new developments have been published. Objectives: This systematic review was designed to assess published reports of SEEG surgical techniques and safety profile. Data sources: An electronic search was performed of Medline, Embase, and Scopus databases. In addition, the content pages of several standard epilepsy surgery textbooks were searched. Full-text English studies describing SEEG surgical technique or pertinent epidemiological data were included. Conference abstracts, reviews, posters, editorials, comments, and letters were excluded. Results: Three hundred fifty-nine of 2,903 potentially eligible studies published by 32 centers were reviewed. Thirty-one of these primarily discussed the surgical technique. Thirty-five major complications (including 4 fatalities) were reported among 4,000 patients (0.8%) implanted with 33,000 electrodes. Limitations: The number of SEEG patients is likely to be underestimated because only a few groups have exhaustively reported their experience. Moreover, it is possible that a number of teams performing SEEG have not published studies on the topic. Conclusions: Rigorous SEEG, thanks to its basic principles and updated technologies, is a safe and accurate method to define the epileptogenic zone by means of stereotactically implanted intracerebral electrodes.Keywords
This publication has 40 references indexed in Scilit:
- Feasibility of multimodal 3D neuroimaging to guide implantation of intracranial EEG electrodesEpilepsy Research, 2013
- Use of robot-guided stereotactic placement of intracerebral electrodes for investigation of focal epilepsy: initial experience in the UKBritish Journal Of Neurosurgery, 2013
- Delayed intracranial hematoma following stereoelectroencephalography for intractable epilepsyJournal of neurosurgery. Pediatrics, 2012
- SEEG-guided RF-thermocoagulation of epileptic foci: A therapeutic alternative for drug-resistant non-operable partial epilepsies2011
- The Cardioinhibitory Responses of the Right Posterior Insular Cortex in an Epileptic PatientStereotactic and Functional Neurosurgery, 2010
- Anatomo-functional Organization of the Insular Cortex in Epileptic HumansNeurosurgery, 2008
- Correlation between Provoked Ictal SPECT and Depth Recordings in Adult Drug‐Resistant Epilepsy PatientsEpilepsia, 2007
- Stereoelectroencephalography in the Presurgical Evaluation of Focal Epilepsy: A Retrospective Analysis of 215 ProceduresNeurosurgery, 2005
- Neurophysiological Monitoring for Epilepsy Surgery: The Talairach SEEG MethodStereotactic and Functional Neurosurgery, 2001
- THE STRUCTURE AND FUNCTIONS OF THE CEREBELLUM EXAMINED BY A NEW METHOD.Brain, 1908