External validation of a rapid algorithm using high-sensitivity troponin assay results for evaluating patients with suspected acute myocardial infarction
- 5 February 2024
- journal article
- research article
- Published by BMJ in Emergency Medicine Journal
- Vol. 41 (5) , 313-319
Abstract
Objective: We sought to validate the clinical performance of a rapid assessment pathway incorporating the Siemens Atellica IM high sensitivity cardiac troponin I (hs-cTnI) assay in patients presenting to the emergency department (ED) with suspected acute myocardial infarction (AMI).Methods: This was a multicentre prospective observational study of adult ED patients presenting to five Australian hospitals between November 2020 and September 2021. Participants included those with symptoms of suspected AMI (without ST-segment elevation MI on presentation ECG). The Siemen’s Atellica IM hs-cTnI laboratory-based assay was used to measure troponin concentrations at admission and after 2–3 hours and cardiologists adjudicated final diagnoses. The HighSTEACS diagnostic algorithm was evaluated, incorporating hs-cTnI concentrations at presentation and absolute changes within the first 2 to 3 hours. The primary outcome was index AMI, including type 1 or 2 non-ST segment elevation MI (NSTEMI) or ST-elevation MI (STEMI) following presentation. 30-day major adverse cardiac outcomes (including AMI, urgent revascularisation or cardiac death) were also reported. The trial was registered with the Australian and New Zealand Clinical Trials Registry.Results: 1994 patients were included. The average age was 56.2 years (SD=15.6), and 44.9% were women. 118 (5.9%) patients had confirmed index AMI. The 2-hour algorithm defined 61.3% of patients as low risk. Sensitivity was 99.1% (94.0%–99.9%) and negative predictive value was 99.9% (99.3%–100%). 24.4% of patients were deemed intermediate risk. When applying the parameters for high risk, 252 (14.3%) were identified, with a specificity of 91.5% (88.7%–93.6%) and a PPV of 42.0% (35.6–48.7%).Conclusions: A 2-hour algorithm based on the HighSTEACS strategy using the Siemens Atellica IM hs-cTnI laboratory-based assay enables safe and efficient risk assessment of emergency patients with suspected AMI.Trial registration number: ACTRN12621000053820.Keywords
Funding Information
- Siemens Healthineers (N/A)
This publication has 22 references indexed in Scilit:
- Single High-Sensitivity Cardiac Troponin I to Rule Out Acute Myocardial InfarctionThe American Journal of Medicine, 2017
- Comparing the No Objective Testing Rule to the HEART PathwayAcademic Emergency Medicine, 2017
- Rapid Rule-out of Acute Myocardial Infarction With a Single High-Sensitivity Cardiac Troponin T Measurement Below the Limit of DetectionAnnals of Internal Medicine, 2017
- National Heart Foundation of Australia & Cardiac Society of Australia and New Zealand: Australian Clinical Guidelines for the Management of Acute Coronary Syndromes 2016Heart, Lung and Circulation, 2016
- A Clinical Decision Rule to Identify Emergency Department Patients at Low Risk for Acute Coronary Syndrome Who Do Not Need Objective Coronary Artery Disease Testing: The No Objective Testing RuleAnnals of Emergency Medicine, 2016
- High-sensitivity cardiac troponin I at presentation in patients with suspected acute coronary syndrome: a cohort studyThe Lancet, 2015
- 2015 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevationEuropean Heart Journal, 2015
- What is an acceptable risk of major adverse cardiac event in chest pain patients soon after discharge from the Emergency Department?International Journal of Cardiology, 2013
- How to use high-sensitivity cardiac troponins in acute cardiac careEuropean Heart Journal, 2012
- Comparison of Early Biomarker Strategies with the Heart Foundation of Australia/Cardiac Society of Australia and New Zealand Guidelines (HFA/CS-ANZ) for Risk Stratification of Emergency Department Patients Presenting with Chest PainHeart, Lung and Circulation, 2012